Tenn. Comp. R. & Regs. 0400-20-11-.17

Current through October 22, 2024
Section 0400-20-11-.17 - TECHNICAL REQUIREMENTS FOR LAND DISPOSAL FACILITIES
(1) Disposal site suitability requirements for land disposal.
(a) The purpose of this paragraph is to specify the minimum characteristics a disposal site must have to be acceptable for use as a disposal facility. The primary emphasis in disposal site suitability is given to isolation of wastes, a matter having long-term impacts and to disposal site features that ensure that the long-term performance objectives of Rule 0400-20-11-.16 are met, as opposed to short-term convenience or benefits.
(b) The disposal site shall be capable of being characterized, modeled, analyzed and monitored.
(c) Within the region where the facility is to be located, a disposal site should be selected so that projected population growth and future developments are not likely to affect the ability of the disposal facility to meet the performance objective of Rule 0400-20-11-.16.
(d) Areas must be avoided having known natural resources which, if exploited, would result in failure to meet the performance objectives of Rule 0400-20-11-.16.
(e) The disposal site must be generally well drained and free of areas of flooding or frequent ponding. Waste disposal shall not take place in a 100-year flood plain or wetland, as defined in Presidential Executive Order 11988, "Floodplain Management Guidelines."
(f) Upstream drainage areas must be minimized to decrease the amount of runoff which could erode or inundate waste disposal units.
(g) The disposal site must provide sufficient depth to the watertable that ground water intrusion, perennial or otherwise, onto waste will not occur. The Department will consider an exception to this requirement to allow disposal below the watertable if it can be conclusively shown that disposal site characteristics will result in molecular diffusion being the predominant means of radionuclide movement and the rate of movement will result in the performance objectives of Rule 0400-20-11-.16 being met. In no case will waste disposal be permitted in the zone of fluctuation of the water table.
(h) The hydrogeologic unit used for disposal shall not discharge ground water to the surface within the disposal site.
(i) Areas must be avoided where tectonic processes such as faulting, folding, seismic activity or vulcanism may occur with such frequency and extent to affect the ability of the disposal site to meet the performance objectives of Rule 0400-20-11-.16, or may preclude defensible modeling and prediction of long-term impacts. .
(j) Areas must be avoided where surface geologic processes such as mass wasting, erosion, slumping, landsliding or weathering occur with such frequency and extent to affect the ability of the disposal site to meet the performance objectives of Rule 0400-20-11-.16, or may preclude defensible modeling and prediction of long-term impacts.
(k) The disposal site must not be located where nearby facilities or activities could impact the ability of the site to meet the performance objectives of Rule 0400-20-11-.16 or mask the environmental monitoring program.
(2) Disposal site design for land disposal.
(a) Site design features must be directed toward long-term isolation and avoidance of the need for continuing active maintenance after site closure.
(b) The disposal site design and operation must be compatible with the disposal site closure and stabilization plan and lead to disposal site closure that provides assurance that the performance objectives of Rule 0400-20-11-.16 will be met.
(c) The disposal site must be designed to complement and improve, where appropriate, the ability of the disposal site's natural characteristics to assure that the performance objectives of Rule 0400-20-11-.16 will be met.
(d) Covers must be designed to minimize to the extent practicable water infiltration, to direct percolating or surface water away from the disposed waste and to resist degradation by surface geologic processes and biotic activity.
(e) Surface features must direct surface water drainage away from disposal units at velocities and gradients which will not result in erosion that will require ongoing active maintenance in the future.
(f) The disposal site must be designed to minimize to the extent practicable the contact of water with waste during storage, the contact of standing water with waste during disposal and the contact of percolating or standing water with wastes after disposal.
(3) Land disposal facility operation and disposal site closure.
(a) Wastes designated as Class A pursuant to paragraph (6) of this rule must be segregated from other wastes by placing in disposal units which are sufficiently separated from disposal units for the other waste classes so that any interaction between Class A wastes and other wastes will not result in the failure to meet the performance objectives in Rule 0400-20-11-.16. This segregation is not necessary for Class A wastes if they meet the stability requirements in subparagraph (7)(b) of this rule.
(b) Wastes designated as Class C pursuant to paragraph (6) of this rule must be disposed of so that the top of the waste is a minimum of 5 meters below the top surface of the cover or must be disposed of with intruder barriers that are designed to protect against an inadvertent intrusion for at least 500 years.
(c) All wastes shall be disposed of in accordance with the requirements of subparagraphs (d) through (k) of this paragraph. .
(d) Wastes must be emplaced in a manner that maintains the package integrity during emplacement, minimizes the void spaces between packages and permits the void spaces to be filled.
(e) Void spaces between waste packages must be filled with earth or other material to reduce future subsidence within the disposal unit.
(f) Waste must be placed and covered in a manner that limits the radiation dose rate at the surface of the cover to levels that at a minimum will permit the licensee to comply with all provisions of Rule 0400-20-11-.60 at the time the license is transferred pursuant to Rule 0400-20-11-.14.
(g) The boundaries and locations of each disposal unit must be accurately located and mapped by means of a land survey. Disposal units must be marked in such a way that the boundaries of each unit can be easily defined. Three permanent survey marker control points, referenced to United States Geological Survey (USGS) or National Geodetic Survey (NGS) survey control stations, must be established on the site to facilitate surveys. The USGS or NGS control stations must provide horizontal and vertical controls as checked against USGS or NGS record files.
(h) A buffer zone of land must be maintained between any disposal unit and the disposal boundary and beneath the disposed waste. The buffer zone shall be of adequate dimensions to carry out environmental monitoring activities specified in paragraph (4) of this rule and take mitigative measures if needed.
(i) Closure and stabilization measures as set forth in the approved site closure plan must be carried out as each disposal unit is filled and covered.
(j) Active waste disposal operations must not have an adverse effect on completed closure and stabilization measures.
(k) Only wastes containing or contaminated with radioactive materials shall be disposed of at the disposal site.
(4) Environmental monitoring.
(a) At the time a license application is submitted, the applicant shall have conducted a pre-operational monitoring program to provide basic environmental data on the disposal site characteristics. The applicant shall obtain information about the ecology, metrology, climate, hydrology, geology, geochemistry and seismology of the disposal site. For those characteristics that are subject to seasonal variation, data must cover at least a 12 month period.
(b) The licensee must have plans for taking corrective measures if migration of radionuclides would indicate that the performance objectives of Rule 0400-20-11-.16 may not be met.
(c) During the land disposal facility site construction and operation, the licensee shall maintain a monitoring program, including a monitoring system. Measurements and observations must be made and recorded to provide data to evaluate the potential health and environmental impacts during both the construction and the operation of the facility and to enable the evaluation of long-term effects and the need for mitigative measures. The monitoring system must be capable of providing early warning of releases of radionuclides from the disposal unit before they leave the site boundary. .
(d) After the disposal site is closed, the licensee responsible for post-operational surveillance of the disposal site shall maintain a monitoring system based on the operating history and the closure and stabilization of the disposal site. The monitoring system must be capable of providing early warning of releases of radionuclides from the disposal unit before they leave the site boundary.
(5) Alternative requirements for design and operations.

The Department may, upon request or on its own initiative, authorize provisions other than those set forth in paragraphs (2), (3) and (4) of this rule for the segregation and disposal of waste and for the design and operation of a land disposal facility on a specific basis, if it finds assurance of compliance with the performance objectives of Rule 0400-20-11-.16.

(6) Waste Classification.
(a) Determination of the classification of radioactive waste involves two considerations. First, consideration must be given to the concentration of long-lived radionuclides (and their short-lived precursors) whose potential hazard will persist long after such precautions as institutional controls, improved waste form and deeper disposal have ceased to be effective. These precautions delay the time when long-lived radionuclides could cause exposures. In addition, the magnitude of the potential dose is limited by the concentration and availability of the radionuclide at the time of exposure. Second, consideration must be given to the concentration of shorter-lived radionuclides for which requirements on institutional controls, waste form and disposal methods are effective.
(b) Classes of waste.
1. Class A waste is waste that is usually segregated from other waste classes at the disposal site. The physical form and characteristics of Class A waste must meet the minimum requirements set forth in subparagraph (7)(a) of this rule. If Class A waste also meets the stability requirements set forth in subparagraph (7)(b) of this rule, it is not necessary to segregate the waste for disposal.
2. Class B waste is waste that must meet more rigorous requirements on waste form to ensure stability after disposal. The physical form and characteristics of Class B waste must meet both the minimum and stability requirements set forth in paragraph (7) of this rule.
3. Class C waste is waste that not only must meet more rigorous requirements on waste form to ensure stability but also requires additional measures at the disposal facility to protect against inadvertent intrusion. The physical form and characteristics of Class C waste must meet both the minimum and stability requirements set forth in paragraph (7) of this rule.
4. Waste that is not acceptable for disposal is waste for which waste form and disposal methods must be different and, in general, more stringent than those specified for Class C waste. In the absence of specific requirements in this Chapter, proposals for disposal of this waste may be submitted to the Department for approval, pursuant to paragraph (9) of this rule.
(c) If radioactive waste contains only radionuclides listed in Table 1, classification shall be determined as follows: .
1. If the concentration does not exceed 0.1 times the value in Table 1, the waste is Class A.
2. If the concentration exceeds 0.1 times the value in Table 1 but does not exceed the value in Table 1, the waste is Class C.
3. If the concentration exceeds the value in Table 1, the waste is not acceptable for disposal, except under part (b)4 of this paragraph.
4. For wastes containing mixtures of radionuclides listed in Table 1, the total concentration shall be determined by the sum of fractions rule described in subparagraph (g) of this paragraph.

Table 1
RadionuclideConcentration curies per cubic meter
C-14 C-14 in activated metal8 80
Ni-59 in activated metal220
Nb-94 in activated metal0.2
Tc-993
I-1290.08
Alpha emitting transuranic nuclides with half-life greater
than five (5) years1001
Pu-2413,5001
Cm-24220,0001

1 Units are nanocuries per gram.

(d) If radioactive waste does not contain any of the radionuclides listed in Table 1, classification shall be determined based on the concentrations shown in Table 2. However, as specified in subparagraph (f) of this paragraph, if radioactive waste does not contain any nuclides listed in either Table 1 or 2, it is Class A.
1. If the concentration does not exceed the value in Column 1, the waste is Class A.
2. If the concentration exceeds the value in Column 1, but does not exceed the value in Column 2, the waste is Class B.
3. If the concentration exceeds the value in Column 2, but does not exceed the value in Column 3, the waste is Class C.
4. If the concentration exceeds the value in Column 3, the waste is not acceptable for disposal, except under part (b)4 of this paragraph.
5. For wastes containing mixtures of the nuclides listed in Table 2, the total concentration shall be determined by the sum of fractions rule described in subparagraph (g) of this paragraph.

Concentration, curies per cubic meterTable 2..
RadionuclideCol. 1Col. 2Col. 3
Total of all nuclides with less than 5 year half life700(1)(1)
H-340(1)(1)
Co-60700(1)(1)
Ni-633.570700
Ni-63 in activated metal357007000
Sr-900.041507000
Cs-1371444600

1 There are no limits established for these radionuclides in Class B or C wastes. Practical considerations such as the effects of external radiation and internal heat generation on transportation, handling and disposal will limit the concentrations for these wastes. These wastes shall be Class B unless the concentrations of other nuclides in Table 2 determine the waste to be Class C independent of these nuclides.

(e) If radioactive waste contains a mixture of radionuclides, some of which are listed in Table 1 and some of which are listed in Table 2, classification shall be determined as follows:
1. If the concentration of a nuclide listed in Table 1 does not exceed 0.1 times the value listed in Table 1, the class shall be that determined by the concentration of nuclides listed in Table 2.
2. If the concentration of a nuclide listed in Table 1 exceeds 0.1 times the value listed in Table 1 but does not exceed the value in Table 1, the waste shall be Class C, provided the concentration of nuclides listed in Table 2 does not exceed the value shown in Column 3 of Table 2.
(f) If radioactive waste does not contain any nuclides listed in either Table 1 or 2, it is Class A.
(g) For determining classification for waste that contains a mixture of radionuclides, it is necessary to determine the sum of fractions by dividing each nuclide's concentration by the appropriate limit and adding the resulting values. The appropriate limits must all be taken from the same column of the same table. The sum of the factions for the column must be less than 1.0 if the waste class is to be determined by that column. Example: a waste contains Sr-90 in a concentration of 50 Ci/m3 and Cs-137 in a concentration of 22 Ci/m3. Since the concentrations both exceed the values in Column 1, Table 2, they must be compared to Column 2 values. For Sr-90 fraction, 50/150=0.33; for Cs-137 fraction, 22/44=0.5; the sum of the fractions=0.83. Since the sum is less than 1.0, the waste is Class B.
(h) The concentration of a radionuclide may be determined by indirect methods such as use of scaling factors which relate the inferred concentration of one radionuclide to another that is measures, or radionuclide material accountability, if there is assurance that the indirect methods can be correlated with actual measurements. The concentration of a radionuclide may be averaged over the volume of the waste, or weight of the waste if the units are expressed as nanocuries per gram.
(7) Waste characteristics.
(a) The following requirements are minimum requirements for all classes of waste and are intended to facilitate handling at the disposal site and provide protection of health and safety of personnel at the disposal site.
1. Waste must not be packaged for disposal in cardboard or fiberboard boxes.
2. Liquid waste must be solidified or packaged in sufficient absorbent material to absorb twice the volume of the liquid.
3. Solid waste containing liquid shall contain as little free standing and noncorrosive liquid as is reasonably achievable, but in no case shall the liquid exceed 1 percent of the volume.
4. Waste must not be capable of detonation or of explosive decomposition or reaction at normal pressures and temperatures or of explosive reaction with water.
5. Waste must not contain, or be capable of generating, quantities of toxic gases, vapors or fumes harmful to persons transporting, handling or disposing of the waste. This does not apply to radioactive gaseous waste packaged in accordance with part (a)7 of this paragraph.
6. Waste must not be pyrophoric. Pyrophoric materials contained in waste shall be treated, prepared and packaged to be nonflammable.
7. Waste in a gaseous form must be packaged at a pressure that does not exceed 1.5 atmospheres at 20o C. Total activity must not exceed 100 curies per container.
8. Waste containing hazardous, biological, pathogenic or infectious material must be treated to reduce to the maximum extent practicable the potential hazard from the non-radiological materials.
(b) The requirements in this paragraph are intended to provide stability of the waste. Stability is intended to ensure that the waste does not structurally degrade and affect overall stability of the site through slumping, collapse or other failure of the disposal unit and thereby lead to water infiltration. Stability is also a factor in limiting exposure to an inadvertent intruder, since it provides a recognizable and nondispersible waste.
1. Waste must have structural stability. A structurally stable waste form will maintain its physical dimensions and its form, under the expected disposal conditions such as weight of overburden and compaction equipment, the presence of moisture, and microbial activity and internal factors such as radiation effects and chemical changes. Structural stability can be provided by the waste form itself, processing the waste to a stable form or placing the waste in a disposal container or structure that provides stability after disposal.
2. Notwithstanding the provisions in parts (a)2 and 3 of this paragraph, liquid wastes, or wastes containing liquid, must be converted into a form that contains as little free standing and noncorrosive liquid as is reasonably achievable, but in no case shall the liquid exceed 1 percent of the volume of the waste when the waste is in a disposal container designed to ensure stability, or one-half percent of the volume of the waste for waste processed to a stable form.
3. Void spaces within the waste and between the waste and its package must be reduced to the extent practicable.
(8) Labeling.

Each package of waste must be clearly labeled to identify whether it is Class A waste, Class B waste or Class C waste in accordance with paragraph (6) of this rule.

(9) Alternative requirements for waste classification characteristics.

The Department may, upon request or on its own initiative, authorize other provisions for the classification and characteristics of waste on a specific basis, if, after evaluation of the specific characteristics of the waste, disposal site and method of disposal, it finds assurance of compliance with the performance objectives in Rule 0400-20-11-.16.

(10) Institutional requirements.
(a) Disposal of radioactive waste received from other persons may be permitted only on land owned in fee by the Federal or State government.
(b) The land owner or custodial agency shall carry out an institutional control program to physically control access to the disposal site following transfer of control of the disposal site from the disposal site operator. The institutional control program must also include, but not be limited to, carrying out an environmental monitoring program at the disposal site, periodic surveillance, minor custodial care, and other requirements as determined by the Department; and administration of funds to cover the costs for these activities. The period of institutional controls will be determined by the Department, but institutional controls may not be relied upon for more than 100 years following transfer of control of the disposal site to the owner.

Tenn. Comp. R. & Regs. 0400-20-11-.17

Original rule filed February 22, 2012; effective May 22, 2012.