S.D. Admin. R. 74:36:07:132

Current through Register Vol. 50, page 162, June 24, 2024
Section 74:36:07:132 - Recordkeeping for existing municipal solid waste landfill Control systems and exceedances

Except as provided in subdivision 74:36:07:126(2), the owner or operator of a control system at an existing municipal solid waste landfill shall keep for five years, readily accessible continuous records of the equipment operating parameters specified to be monitored in §§ 74:36:07:117 to 74:36:07:124, inclusive, and records for periods of operation during which the parameter boundaries established during the most recent performance test are exceeded. The following records meet this requirement:

(1) The following constitute exceedances that must be recorded:
(a) For enclosed combustors, except for boilers and process heaters with design heat input capacity of 44 megawatts (150 million British thermal unit per hour) or greater, all 3-hour periods of operation during which the average temperature was more than 28 degrees Celsius (82 degrees Fahrenheit) below the average combustion temperature during the most recent performance test at which compliance with § 74:36:07:109 was determined; and
(b) For boilers or process heaters, whenever there is a change in the location at which the vent stream is introduced into the flame zone;
(2) The indication of flow to the control system and the indication of bypass flow or records of monthly inspections of car-seals or lock-and-key configurations used to seal bypass lines;
(3) If a boiler or process heater with a design heat input capacity of 44 megawatts or greater is used to comply with § 74:36:07:109, keep records of all periods of operation of the boiler or process heater;
(4) If using a non-enclosed flare, keep continuous records of the flame or flare pilot flame monitoring, and records of all periods of operation in which the flame or flare pilot flame is absent; and
(5) If complying with § 74:36:07:98 using an active collection system, keep records of periods when the collection system or control device is not operating.

S.D. Admin. R. 74:36:07:132

46 SDR 064, effective 11/25/2019

General Authority: SDCL 34A-1-6.

Law Implemented: SDCL 34A-1-18.