The Secretary shall approve the control system if it meets one of the following requirements, except as provided in 40 C.F.R. § 60.24 (July 1, 2018):
Route the collected gas to a treatment system that processes the collected gas for subsequent sale or beneficial use or use as a raw material in a chemical manufacturing process. Venting of treated landfill gas to the ambient air is not allowed. If the treated landfill gas cannot be routed for subsequent sale or beneficial use, the treated landfill gas shall be controlled according to subdivision (1), (2) or (3) of this section. All emissions from any atmospheric vent from the gas treatment system are subject to the requirements of §§ 74:36:07:106 and 74:36:07:107 or subdivision (1), (2), or (3) of this section. Atmospheric vents located on the condensate storage tank are not part of the treatment system and exempt from the requirements of this subdivision.
If a boiler or process heater is used as a control device, the landfill gas stream shall be introduced into the flame zone. The control device shall be operated within the operating parameter ranges established during the initial or most recent performance test. For the closed landfill subcategory, the initial or most recent performance test conducted on or before July 17, 2014 satisfies the performance testing requirements;
S.D. Admin. R. 74:36:07:109
General Authority: SDCL 34A-1-6.
Law Implemented: SDCL 34A-1-18.