S.D. Admin. R. 20:10:39:32

Current through Register Vol. 50, page 159, June 17, 2024
Section 20:10:39:32 - Recording the cow contact test data

The person conducting the cow contact test shall record the location of, and measured values at, each test point. At each cow contact location, an open circuit voltage reading and a voltage reading with the shunt resistor placed across the input to the meter are taken. These readings are taken with ten seconds or less time between each reading. Alternatively, a current measurement may be taken in place of the voltage measurement. Data for these test points are recorded on the cow contact test form on file with the commission.

S.D. Admin. R. 20:10:39:32

42 SDR 174, effective 6/21/2016

General Authority: SDCL 49-47-2.

Law Implemented: SDCL 49-47-2, 49-47-3.