Current through Register Vol. 48, No. 10, October 25, 2024
Section 61-86.1.IX - EXEMPTION FROM WETTING FOR ANY SIZED PROJECTA. General Provisions. In renovation operations, wetting is not required if:
1. The owner/operator has obtained prior written approval from the Department based on a written application that wetting to comply with this Section would unavoidably damage equipment or present a safety hazard; and2. The owner/operator uses one or more of the following emission control methods: a. A local exhaust ventilation and collection system designed and operated to capture the particulate asbestos material produced by the stripping and removal of asbestos materials. The system must exhibit no visible emissions to the outside air or must be designed and operated in accordance with the requirements in EPA Regulation 40 CFR 61.152, as amended, and any subsequent amendments and editions;b. A glovebag system designed and operated in accordance with the requirements of OSHA regulation 29 CFR 1926.1101, as amended, and any subsequent amendments and editions;c. Leak-tight wrapping to contain all RACM prior to dismantlement;3. In renovation operations where wetting would result in equipment damage or a safety hazard and the methods allowed in this Section cannot be used, an owner or operator may use another method after obtaining written approval from the Department based on its determination that the alternative method is equivalent to wetting. The owner/operator shall keep a copy of the Department's written approval at the work site and make it available for review by Department personnel upon request.B. Temperature Constraints. When the temperature at the point of wetting is below 0° C (32° F):
1. During periods when wetting operations are suspended due to freezing temperatures, the owner/operator must record the temperature in the area containing the asbestos-coated or covered facility components at the beginning, middle, and end of each workday and keep daily temperature records. A copy of these records must be maintained at the project site and made available for inspection by Department personnel upon request. The facility owner must maintain these temperature records for two years from the date the project is completed and shall provide a legible copy of the data to the Department upon request.2. The owner/operator may request to use an alternative work practice by submitting to the Department a written description of control measures to be used that will afford the same level of protection as wetting. A legible copy of the Department's approval letter must be available at the project site for the duration of the asbestos project and shall be made available for review by Department personnel upon request.3. The owner/operator shall remove facility components containing, coated with, or covered with RACM as units or in sections and shall secure the units or sections leak-tight in 6-mil or thicker polyethylene sheeting.S.C. Code Regs. § 61-86.1.IX