Current through Register Vol. 48, 12, December 27, 2024
Section 61-79.270.B.21 - Specific Part B information requirements for landfillsExcept as otherwise provided in R.61-79.264.1, owners and operators of facilities that dispose of hazardous waste in landfills must provide the following additional information:
(a) A list of the hazardous wastes placed or to be placed in each landfill or landfill cell;(b) Detailed plans and an engineering report describing how the landfill is designed and is or will be designed, constructed, operated, and maintained to meet the requirements of 264.19, 264.301, 264.302, and 264.303, addressing the following items: (1)(i) The liner system (except for an existing portion of a landfill), if the landfill must meet the requirements of 264.301(a). If an exemption from the requirement for a liner is sought as provided by R.61-79.264.301(b)(b), submit detailed plans, and engineering and hydrogeological reports, as appropriate, describing alternate designs and operating practices that will, in conjunction with location aspects, prevent the migration of any hazardous constituents into the groundwater or surface water at any future time; (amended 11/90)(ii) The double liner and leak (leachate) detection, collection, and removal system, if the landfill must meet the requirements of section264.301(d), (e), or (f)(c). If an exemption from the requirements for double liners and a leak detection, collection, and removal system or alternative design is sought as provided by section264.301(c)(d), (e), or (f) of this chapter, submit appropriate information;(iii) If the leak detection system is located in a saturated zone, submit detailed plans and an engineering report explaining the leak detection system design and operation, and the location of the saturated zone in relation to the leak detection system;(iv) The construction quality assurance (CQA) plan if required under section264.19;(v) Proposed action leakage rate, with rationale, if required under section264.302 of this chapter, and response action plan, if required under section264.303 of this chapter;(4) Management of collection and holding facilities associated with run-on and run-off control systems; and(5) Control of wind dispersal of particulate matter, where applicable.(c) A description of how each landfill, including the double liner system, leachate collection and removal system leak detection system, cover system, and appurtenances for control of run-on and run-off, will be inspected in order to meet the requirements of 264.303(a), (b), and (c) of this chapter. This information must be included in the inspection plan submitted under 270.14(b)(5);(d) A description of how each landfill, including the liner and cover systems, will be inspected in order to meet the requirements of R.61-79.264.303(a) and (b)(a) and (b). This information should be included in the inspection plan submitted under paragraph 270.14(b)(5);(e) Detailed plans and an engineering report describing the final cover which will be applied to each landfill or landfill cell at closure in accordance with R.61-79.264.310(a)(a), and a description of how each landfill will be maintained and monitored after closure in accordance with R.61-79.264.310(b)(b). This information should be included in the closure and postclosure plans submitted under 270.14(b)(13).(f) If ignitable or reactive wastes will be landfilled, an explanation of how the standards of R.61-79.264.312 will be complied with;(g) If incompatible wastes, or incompatible wastes and materials will be landfilled, and explanation of how R.61-79.264.313 will be complied with;(i) If containers of hazardous waste are to be landfilled, an explanation of how the requirements of 264.315 or 264.316, as applicable, will be complied with](j) A waste management plan for Hazardous Waste Nos. F020, F021, F022, F023, F026, and F027 describing how a landfill is or will be designed, constructed, operated, and maintained to meet the requirements of R.61-79.264.317. This submission must address the following items specified in Section264.317: (1) The volume, physical, and chemical characteristics of the wastes, including their potential to migrate through soil or to volatilize or escape into the atmosphere;(2) The attenuating properties of underlying and surrounding soils or other materials;(3) The mobilizing properties of other materials co-disposed with these wastes; and(4) The effectiveness of additional treatment, design, or monitoring techniques.(k) An estimate with justifying documentation will specify how long the facility shall be expected to meet the designed minimum technology requirements after closure.S.C. Code Regs. § 61-79.270.B.21
Amended by State Register Volume 10, Issue No. 1, eff January 24, 1986; State Register Volume 11, Issue No. 11, eff November 27, 1987; State Register Volume 13, Issue No. 6, eff June 23, 1989; State Register Volume 14, Issue No. 11, eff November 23, 1990; tate Register Volume 16, Issue No. 12, eff December 25, 1992; State Register Volume 17, Issue No. 12, eff December 24, 1993; State Register Volume 24, Issue No. 8, eff August 25, 2000.