S.C. Code Regs. § § 61-79.270.B.16

Current through Register Vol. 48, 12, December 27, 2024
Section 61-79.270.B.16 - Specific Part B information requirements for tank systems

Except as otherwise provided in R.61-79.264.190, owners and operators of facilities that use tanks to store or treat hazardous waste must provide the following additional information.

(a) A written assessment that is reviewed and certified by a qualified Professional Engineer as to the structural integrity and suitability for handling hazardous waste of each tank system, as required under 264.191 and 264.192;
(b) Dimensions and capacity of each tank;
(c) Description of feed systems, safety cutoff, bypass systems, and pressure controls (e.g., vents);
(d) A diagram of piping, instrumentation, and process flow for each tank system;
(e) A description of materials and equipment used to provide external corrosion protection, as required under 264.192(a)(3)(ii).
(f) For new tank systems, a detailed description of how the tank system(s) will be installed in compliance with R.61-79.264.192(b), (c), (d), and (e)(b), (c), (d), and (e);
(g) Detailed plans and descriptions of how the secondary containment system for each tank system is or will be designed, constructed, and operated to meet the requirements of 264.193(a), (b), (c), (d), (e), and (f);
(h) For tank systems for which a variance from the requirements of R.61-79.264.193 is sought (as provided by Section264.193(g)(g)):
(1) Detailed plans and engineering and hydrogeologic reports, as appropriate, describing alternate design and operating practices that will, in conjunction with location aspects, prevent the migration of any hazardous waste or hazardous constituents into the groundwater or surface water during the life of the facility, or
(2) A detailed assessment of the substantial present or potential hazards posed to human health or the environment should a release enter the environment.
(i) Description of controls and practices to prevent spills and overflows, as required under R.61-79.264.194(b)(b); and
(j) For tank systems in which ignitable, reactive, or incompatible wastes are to be stored or treated, a description of how operating procedures and tank system and facility design will achieve compliance with the requirements of R.61-79.264.198 and 264.199.
(k) Information on air emission control equipment as required in 270.27.

S.C. Code Regs. § 61-79.270.B.16

Amended by State Register Volume 10, Issue No. 1, eff January 24, 1986; State Register Volume 11, Issue No. 11, eff November 27, 1987; State Register Volume 14, Issue No. 11, eff November 23, 1990; State Register Volume 22, Issue No. 9, Part 2, eff September 25, 1998; State Register Volume 32, Issue No. 6, eff June 27, 2008.