S.C. Code Regs. § ch. 61, 61-79, 61-79.268, app 61-79.268.VI

Current through Register Vol. 48, 12, December 27, 2024
Appendix 61-79.268.VI - Recommended Technologies to Achieve Deactivation of Characteristics in Section 268.42

The treatment standard for many characteristic wastes is stated in the 268.40 Table of Treatment Standards as "Deactivation and meet UTS." EPA has determined that many technologies, when used alone or in combination, can achieve the deactivation portion of the treatment standard. Characteristic wastes that are not managed in a facility regulated by the Clean Water Act (CWA) or in a CWA-equivalent facility, and that also contain underlying hazardous constituents (see 268.2(i)) must be treated not only by a "deactivating" technology to remove the characteristic, but also to achieve the universal treatment standards (UTS) for underlying hazardous constituents. The following appendix presents a partial list of technologies, utilizing the five letter technology codes established in 268.42 Table 1, that may be useful in meeting the treatment standard. Use of these specific technologies is not mandatory and does not preclude direct reuse, recovery, and/or the use of other pretreatment technologies, provided deactivation is achieved and underlying hazardous constituents are treated to achieve the UTS.

Waste

code/subcategory

Nonwaste waters

Waste waters

D001

Ignitable Liquids based on 261-21(a)(1)--Low TOC Nonwastewater Subcategory (containing 1% to <10% TOC)

RORGS INCIN WETOX CHOXD BIODG

n.a.

D001

Ignitable Liquids based on 261-21(a)(1)--Ignitable Wastewater Subcategory (containing <1% TOC)

n.a.

RORGS INCIN WETOX CHOXD BIODG

D001

Compressed Gases based on 261-21(A)(3)

RCGAS INCIN FSUBS ADGAS fb. INCIN ADGAS fb. (CHOXD: or CHRED)

n.a.

D001

Ignitable Reactives based on 261-21(a)(2)

WTRRX CHOXD CHRED STABL INCIN

n.a.

D001

Ignitable Oxidizers based on 261-21(a)(4)

CHRED INCIN

CHRED INCIN

D002

Acid Subcategory based on 261-22(a)(1) with pH less than or equal to 2

RCORR NEUTR INCIN

NEUTR INCIN

D002

Alkaline Subcategory based on 261-22(a)(1) with pH greater than or equal to 12.5

NEUTR INCIN

NEUTR INCIN

D002

Other Corrosives based on

261-22(a)(2)

CHOXD CHRED INCIN STABL

CHOXD CHRED INCIN

D003

Water Reactives based on 261-23(a)(2), (3), and (4)

INCIN WTRRX CHOXD CHRED

n.a.

D003

Reactive Sulfides based on 261-23(a)(5)

CHOXD CHRED INCIN STABL

CHOXD CHRED BIODG INCIN

D003

Explosives based on 261-23(a)(6), (7), and (8)

INCIN CHOXD CHRED

INCIN CHOXD CHRED BIODG CARBN

D003

Other Reactives based on 261-23(a)(1)

INCIN CHOXD CHRED

INCIN CHOXD CHRED BIODG CARBN

K044

Wastewater treatment sludges from the manufacturing and processing of explosives

CHOXD CHRED INCIN

CHOXD CHRED BIODG CARBN INCIN

K045

Spent carbon from the treatment of wastewaters containing explosives

CHOXD CHRED INCIN

CHOXD CHRED BIODG CARBN INCIN

K047

Pink/red water from TNT operations

CHOXD CHRED INCIN

CHOXD CHRED BIODG CARBN INCIN

FOOTNOTE: Note: "n.a." stands for "not applicable"; "fb." stands for "followed by".

S.C. Code Regs. ch. 61, 61-79, 61-79.268, app 61-79.268.VI

Added by State Register Volume 16, Issue No. 12, eff December 25, 1992; Amended by State Register Volume 22, Issue No. 9, Part 2, eff September 25, 1998.