S.C. Code Regs. § § 61-79.262.C.32

Current through Register Vol. 48, 12, December 27, 2024
Section 61-79.262.C.32 - Marking
(a) Before transporting or offering hazardous waste for transportation offsite, a generator must mark each package of hazardous waste in accordance with the applicable S. C. Public Service Commission regulations and Federal Department of Transportation regulations on hazardous materials under 49 CFR Part 172;
(b) Before transporting hazardous waste or offering hazardous waste for transportation off-site, a generator must mark each container of 119 gallons or less used in such transportation with the following words and information in accordance with the requirements of 49 CFR 172.304:
(1) HAZARDOUS WASTE - Federal Law Prohibits Improper Disposal. If found, contact the nearest police or public safety authority or the U.S. Environmental Protection Agency.
(2) Generator's Name and Address
(3) Generator's EPA Identification Number
(4) Manifest Tracking Number
(5) EPA Hazardous Waste Number(s)
(c) A generator may use a nationally recognized electronic system, such as bar coding, to identify the EPA Hazardous Waste Number(s), as required by paragraph (b)(5) or paragraph (d).
(d) Lab packs that will be incinerated in compliance with section 268.42(c) are not required to be marked with EPA Hazardous Waste Number(s), except D004, D005, D006, D007, D008, D010, and D011, where applicable.

S.C. Code Regs. § 61-79.262.C.32

Amended by State Register Volume 13, Issue No. 6, eff June 23, 1989; State Register Volume 14, Issue No. 11, eff November 23, 1990; State Register Volume 16, Issue No. 12, eff December 25, 1992; State Register Volume 17, Issue No. 5, Part 2, eff May 28, 1993; State Register Volume 21, Issue No. 6, Part 2, eff June 27, 1997; State Register Volume 31, Issue No. 2, eff February 23, 2007; State Register Volume 36, Issue No. 9, eff September 28, 2012; State Register Volume 43, Issue No. 05, eff. 5/24/2019.