If any of the information provided to the Department changes, the Department shall be notified at least 24 hours prior to well construction.
All monitoring wells shall be properly labeled with an identification plate immediately upon well completion. The identification plate shall be constructed of a durable, weatherproof, rustproof, material. The identification plate shall be permanently secured to the well casing or enclosure floor around the casing where it is readily visible. The identification plate shall be permanently marked to show:
Development shall be complete when the well produces water typical of the aquifer being utilized.
Abandonment shall be by forced injection of grout or pouring through a tremie pipe starting at the bottom of the well and proceeding to the surface in one continuous operation. The well shall be filled with either with neat cement, bentonite-cement, or 20% high solids sodium bentonite grout, from the bottom of the well to the land surface.
All monitoring wells shall be properly labeled with an identification plate immediately upon well completion. The identification plate shall be constructed of a durable, weatherproof, rustproof, material. The identification plate shall be permanently secured to the well casing or enclosure floor around the casing where it is readily visible. The identification plate shall be permanently marked to show:
Development shall be complete when the well produces water typical of the aquifer being utilized.
Additional Requirements For Temporary Monitoring Wells
All temporary monitoring wells shall be sealed with a watertight cap or seal until abandoned. Temporary monitoring wells shall be maintained such that they are not a source or channel of contamination before they are abandoned.
Use of Water Wells as Monitoring Wells.
Due to the variability involved, the use of a potable water well as a monitoring well shall be approved by the Department on a case-by-case basis.
Non-Standard Monitoring Wells
Due to the variability involved, the use of construction methods, techniques, or monitoring well designs not covered in this regulation shall be approved by the Department on a case-by-case basis.
S.C. Code Regs. 61-71.H