TABLE 1: QUALITY FACTORS AND ABSORBED DOSE EQUIVALENCIES | ||
TYPE OF RADIATION | Quality Factor (Q) | Absorbed dose equal to a unit dose equivalent [FN2] |
X-, gamma, or beta radiation | 1 | 1 |
Alpha particles, multiple-charged particles, fission fragments and heavy particles of unknown charge...... | 20 | 0.05 |
Neutrons of unknown energy ............. | 10 | 0.1 |
High'energy protons .................... | 10 | 0.1 |
[FN2] Absorbed dose in rad equal to 1 rem or the absorbed dose in gray equal to 1 sievert. |
TABLE 2: MEAN QUALITY FACTORS, Q, AND FLUENCE PER UNIT DOSE EQUIVALENT FOR MONOENERGETIC NEUTRONS | ||
Neutron Energy (MeV) | Quality Factor [FNa] (Q) | Fluence per Unit Dose Equivalent [FNb] (neutrons cm-2 rem-1) |
(thermal) ........... 2.5 x 10-8 | 2 | 980 x 106 |
1 x 10-7 | 2 | 980 x 106 |
1 x 10-6 | 2 | 810 x 106 |
1 x 10-5 | 2 | 810 x 106 |
1 x 10-4 | 2 | 840 x 106 |
1 x 10-3 | 2 | 980 x 106 |
1 x 10-2 | 2.5 | 1010x 106 |
1 x 10-1 | 7.5 | 170 x 106 |
5 x 10-1 | 11 | 39 x 106 |
1 | 11 | 27 x 106 |
2.5 | 9 | 29 x 106 |
5 | 8 | 23 x 106 |
7 | 7 | 24 x 106 |
10 | 6.5 | 24 x 106 |
14 | 7.5 | 17 x 106 |
20 | 8 | 16 x 106 |
40 | 7 | 14 x 106 |
60 | 5.5 | 16 x 106 |
1 x 102 | 4 | 20 x 106 |
2 x 102 | 3.5 | 19 x 106 |
3 x 102 | 3.5 | 16 x 106 |
4 x 102 | 3.5 | 14 x 106 |
[FNa] Value of quality factor (Q) at the point where the dose equivalent is maximum in a 30-cm diameter cylinder tissue-equivalent phantom. | ||
[FNb] Monoenergetic neutrons incident normally on a 30-cm diameter cylinder tissue-equivalent phantom. |
S.C. Code Regs. § 61-63.III.RHA 3.3