S.C. Code Regs. § § 61-62.5.3.1.XI

Current through Register Vol. 48, No. 9, September 27, 2024
Section 61-62.5.3.1.XI - Inspection Guidelines
(a) The owner or operator of an affected facility shall ensure that the HMIWI has an initial equipment inspection performed within one year of the effective date of this Standard. The inspection shall not relieve the owner or operator from any detected violations.
(1) At a minimum, an inspection shall include the following:
(i) Inspect all burners, pilot assemblies, and pilot sensing devices for proper operation; clean pilot flame sensor, as necessary;
(ii) Ensure proper adjustment of primary and secondary chamber combustion air, and adjust as necessary;
(iii) Inspect hinges and door latches and lubricate as necessary;
(iv) Inspect dampers, fans, and blowers for proper operation;
(v) Inspect HMIWI door and door gaskets for proper sealing;
(vi) Inspect motors for proper operation;
(vii) Inspect primary chamber refractory lining; clean and repair/replace lining as necessary;
(viii) Inspect incinerator shell for corrosion and/or hot spots;
(ix) Inspect secondary/tertiary chamber and stack, clean as necessary;
(x) Inspect mechanical loader, including limit switches, for proper operation, if applicable;
(xi) Visually inspect waste bed (grates), and repair/seal, as appropriate;
(xii) For the burn cycle that follows the inspection, document that the incinerator is operating properly and make any necessary adjustments;
(xiii) Inspect air pollution control device(s) for proper operation, if applicable;
(xiv) Inspect waste heat boiler systems to ensure proper operation, if applicable;
(xv) Inspect bypass stack components;
(xvi) Ensure proper calibration of thermocouples, sorbent feed systems and any other monitoring equipment; and
(xvii) Generally observe that the equipment is maintained in good operating condition.
(2) Within 10 operating days following an equipment inspection the owner or operator of an affected facility shall ensure that all necessary repairs shall be completed. In order to exceed the 10 days, the owner or operator must justify the extension and obtain written approval from the Department establishing a date whereby all necessary repairs of the designated facility shall be completed.
(b) The owner or operator of an affected facility shall ensure that the HMIWI has an equipment inspection performed annually (no more than 12 months following the previous annual equipment inspection), as outlined in paragraphs (a)(1) and (a)(2) of this section.

S.C. Code Regs. § 61-62.5.3.1.XI