Current through Register Vol. 48, 12, December 27, 2024
Section 61-109.1600.1602 - Procedure RoomsA. The procedure room shall be sized to accommodate necessary equipment or supplies, staff, and procedure table, but not less than sixty-four (64) square feet of floor space, exclusive of fixed cabinets or shelves. The procedure room shall be utilized exclusively for body piercing. Multiple work stations shall be separated by dividers, curtains, walls, or partitions measuring at least four (4) feet in height. 1. Wall and floor surfaces of the procedure and disinfection or sterilization rooms shall be nonporous and easily cleanable.2. A separate, properly identified sink, with hot and cold running water, used for disinfection practices only shall be located in the disinfection or sterilization room.B. Procedure tables shall be constructed of a nonporous, sanitizable material.C. Each procedure room shall have a high efficiency particulate air (HEPA) filter.S.C. Code Regs. § 61-109.1600.1602
Added by State Register Volume 40, Issue No. 05, eff. 5/27/2016.