S.C. Code Regs. § § 103-702.6

Current through Register Vol. 48, No. 11, November 22, 2024
Section 103-702.6 - Error in Registration

The percentage by which the correct registration varies from the meter registration. The error is derived by stopping the meter test hand at the starting point and then determining the percentage variation in registration as indicated by the working standard. The formula for determining the error in registration is:

100

x

(Meter Reading-Actual Volume)

(Actual Volume)

A positive percentage indicates a fast meter and a negative percentage indicates the meter is slow.

S.C. Code Regs. § 103-702.6