250 R.I. Code R. 250-RICR-120-05-39.18

Current through November 7, 2024
Section 250-RICR-120-05-39.18 - Table III: Operating Parameters to be Monitored and Minimum Measurement and Recording Frequencies

Operating parameters to be monitored

Minimum frequency

Control system

Data measuremen t

Data recording

Dry scrubber followed by fabric filter

Wet scrubber

Dry scrubber followed by fabric filter and wet scrubber

Maximum operating parameters

Maximum charge rate

continuous

1 per hour

[TICK]

[TICK]

[TICK]

Maximum fabric filter inlet temperature

continuous

1 per minute

[TICK]

[TICK]

Maximum flue gas temperature

continuous

1 per minute

[TICK]

Minimum operating parameters

Minimum secondary chamber temperature

continuous

1 per minute

[TICK]

[TICK]

[TICK]

Minimum dioxin/furan sorbent flow rate

hourly

1 per hour

[TICK]

[TICK]

Minimum HCl sorbent flow rate

hourly

1 per hour

[TICK]

[TICK]

Minimum mercury (Hg) sorbent flow rate

hourly

1 per hour

[TICK]

[TICK]

Minimum pressure drop across the wet scrubber or minimum horsepower or amperage to wet scrubber

continuous

1 per minute

[TICK]

[TICK]

Minimum scrubber liquor flow rate

continuous

1 per minute

[TICK]

[TICK]

Minimum scrubber liquor pH

continuous

1 per minute

[TICK]

[TICK]

250 R.I. Code R. 250-RICR-120-05-39.18

Amended effective 12/26/2018