Operating parameters to be monitored | Minimum frequency | Control system | |||
Data measuremen t | Data recording | Dry scrubber followed by fabric filter | Wet scrubber | Dry scrubber followed by fabric filter and wet scrubber | |
Maximum operating parameters | |||||
Maximum charge rate | continuous | 1 per hour | [TICK] | [TICK] | [TICK] |
Maximum fabric filter inlet temperature | continuous | 1 per minute | [TICK] | [TICK] | |
Maximum flue gas temperature | continuous | 1 per minute | [TICK] | ||
Minimum operating parameters | |||||
Minimum secondary chamber temperature | continuous | 1 per minute | [TICK] | [TICK] | [TICK] |
Minimum dioxin/furan sorbent flow rate | hourly | 1 per hour | [TICK] | [TICK] | |
Minimum HCl sorbent flow rate | hourly | 1 per hour | [TICK] | [TICK] | |
Minimum mercury (Hg) sorbent flow rate | hourly | 1 per hour | [TICK] | [TICK] | |
Minimum pressure drop across the wet scrubber or minimum horsepower or amperage to wet scrubber | continuous | 1 per minute | [TICK] | [TICK] | |
Minimum scrubber liquor flow rate | continuous | 1 per minute | [TICK] | [TICK] | |
Minimum scrubber liquor pH | continuous | 1 per minute | [TICK] | [TICK] |
250 R.I. Code R. 250-RICR-120-05-39.18