250 R.I. Code R. 250-RICR-120-05-30.11

Current through December 26, 2024
Section 250-RICR-120-05-30.11 - Compliance Demonstration/Testing
A. Compliance with emission limitations of §§ 30.7(A), 30.7(A)(1), and 30.7(B) of this Part shall be demonstrated upon request of the Director in accordance with 40 C.F.R. § 60, Appendix A, Methods 24, 24A, 25 or any other EPA approved method which has been accepted by the Director. A one hour bake time must be used for Methods 24 and 24A. Methods 24 and 24A apply to multicomponent coatings.
B. (Reserved for stack exhaust sampling techniques.)
C. Facilities using control equipment to comply with the emission limitations of §§ 30.7(A) and 30.7(A)(1) of this Part must show that the equipment meets specific capture and control efficiency limits which will be set in an enforceable document. Compliance must be demonstrated upon equipment start up and thereafter upon request of the Director. Control efficiency of the equipment shall be determined using EPA-approved test methods. Calculations shall be done on a solids applied basis. Compliance averaging times shall be met according to the control device chosen and EPA test methods (as codified in 40 C.F.R. § 60), as follows:

TABLE 3

Compliance Method

EPA Reference Test Method

Test Averaging Time

Solvent destruction or solvent recovery except carbon adsorption

25

3 hours

Carbon adsorption

25 or other test method as appropriate

The length of adsorption cycle or 24-hours, which-ever is less.

1. or other methods approved by the Department and EPA. Once the control efficiency has been determined for any control device by Reference Method 25, or any alternative method approved by the Department and EPA, compliance shall be determined on an instantaneous basis time period (e.g. determined control efficiency shall be used to calculate whether samples from the process meet the applicable emissions limit.) Continuous compliance will be maintained at all times.
D. Compliance with transfer efficiency requirements specified in § 30.8(A)(3) of this Part shall be demonstrated using a method acceptable to the Department and EPA.

250 R.I. Code R. 250-RICR-120-05-30.11