TABLE 2 - REPORTING TERMS AND RESPONSES | ||
Level of Detection (with respect to MCL or HA) | Reporting Terms | Response. Any obvious change in water quality shall dictate consultation and retesting. |
Detect up to 50% MCL or HA | Present | Note presence - monitor on regular schedule |
>50% up to MCL or HA | Action Level | Monitor with more frequent testing (perhaps 1/2 suggested testing interval) - consider remediation or treatment options |
> MCL or HA but < 10x | Elevated | Minimize ingestion and use bottled water. Water may still be used for other household purposes. Continued use may be dependent on the nature of the constituent. Retest immediately and seek remediation or treatment. |
> Or = 10 x MCL or HA | Extremely Elevated | Discontinue use for all purposes |
For SMCLs | Exceedance | Treatment is recommended not required |
216 R.I. Code R. 216-RICR-50-05-2.14