Section 47.242 - Construction
(a) Toeboards shall be constructed in a permanent and substantial manner of metal, wood or other material that is equivalent in strength. Perforations up to 1/2 inch is permitted. Toeboards shall be smooth and free from protruding nails, bolts, splinters, fins and slivers.
(b) Wood toeboards shall be at least equal in cross section to 1 inch by 6 inches finished size. Sheet metal toeboards shall be at least 1/8 inch by 6 inches. When other material is used, the strength shall be equal to the requirement for sheet metal. Reference should be made to Plates 1,2,3, and 5 of the Appendix.
(c) Toeboards shall fit tightly to the floor and fastened by straps or angles secured by bolts or rivets. If possible the toeboard shall be fastened to the post or upright of the railing. Reference should be made to Plates 1-A,C; 2-A,B,C; 3-A,C; 5-A of the Appendix.

34 Pa. Code § 47.242

This section cited in 34 Pa. Code § 47.291 (relating to exceptions).