Table 1
VOC Content Limits for Architectural and Industrial Maintenance Coatings
The VOC content limits are effective on January 1, 2005, and are expressed in grams of VOC per liter1 of coating thinned to the manufacturer's maximum recommendation, excluding the volume of any water, exempt compounds, or colorant added to tint bases. "Manufacturer's maximum recommendation" means the maximum recommendation for thinning that is indicated on the label or lid of the coating container.
Coating Category | VOC Content Limit |
Nonspecialty Coatings | |
Flat Coatings | 100 |
Nonflat Coatings | 150 |
Nonflat High Gloss Coatings | 250 |
Specialty Coatings | |
Antenna Coatings | 530 |
Antifouling Coatings | 400 |
Bituminous Roof Coatings | 300 |
Bituminous Roof Primers | 350 |
Bond Breakers | 350 |
Calcimine Recoaters | 475 |
Clear Wood Coatings | |
-Clear Brushing Lacquers | 680 |
-Conversion Varnish | 725 |
-Sanding Sealers (other than Lacquer Sanding Sealers) | 350 |
-Varnishes | 350 |
1 Conversion factor: 1 pound VOC per gallon (U.S.) = 119.95 grams per liter.
Coating Category | VOC Content Limit |
Concrete Curing Compounds | 350 |
Concrete Surface Retarders | 780 |
Dry Fog Coatings | 400 |
Faux Finishing Coatings | 350 |
Fire-Resistive Coatings | 350 |
Fire-Retardant Coatings | |
-Clear | 650 |
-Opaque | 350 |
Floor Coatings | 250 |
Flow Coatings | 420 |
Form-Release Compounds | 250 |
Graphic Arts Coatings (Sign Paints) | 500 |
High-Temperature Coatings | 420 |
Impacted Immersion Coatings | 780 |
Industrial Maintenance Coatings | 340 |
Lacquers (including Lacquer Sanding Sealers) | 550 |
Low-Solids Coatings | 1202 |
Magnesite Cement Coatings | 450 |
Mastic Texture Coatings | 300 |
Metallic Pigmented Coatings | 500 |
Multi-Color Coatings | 250 |
Nuclear Coatings | 450 |
Pretreatment Wash Primers | 420 |
Primers, Sealers, and Undercoaters | 200 |
Quick-Dry Enamels | 250 |
Quick-Dry Primers, Sealers and Undercoaters | 200 |
Recycled Coatings | 250 |
Roof Coatings | 250 |
Rust-Preventive Coatings | 400 |
Shellacs | |
-Clear | 730 |
-Opaque | 550 |
Specialty Primers, Sealers and Undercoaters | 350 |
Stains | 250 |
2 Including water and exempt solvents
Coating Category | VOC Content Limit |
Swimming Pool Coatings | 340 |
Swimming Pool Repair and Maintenance Coatings | 340 |
Temperature-Indicator Safety Coatings | 550 |
Thermoplastic Rubber Coatings and Mastic | 550 |
Traffic Marking Coatings | 150 |
Waterproofing Sealers | 250 |
Waterproofing Concrete/Masonry Sealers | 400 |
Wood Preservatives | 350 |
25 Pa. Code § 130.603
This section cited in 25 Pa. Code § 130.606 (relating to application for variance); 25 Pa. Code § 130.607 (relating to variance orders); 25 Pa. Code § 130.609 (relating to extension, modification or revocation of variance); and 25 Pa. Code § 130.611 (relating to compliance provisions and test methods).