Where:
EHIweighted = The heat input fuel weighted multiple fuel emission rate or emission limitation for the compliance period, expressed in units of measure consistent with the units of measure for the emission limitation.
Ei = The emission rate or emission limit for fuel i during the compliance period, expressed in units of measure consistent with the units of measure for the emission limitation.
HIi = The total heat input for fuel i during the compliance period.
n = The number of different fuels used during the compliance period.
25 Pa. Code § 129.97
The provisions of this §129.97 issued under section 5(a)(1) and (8) of the Air Pollution Control Act (35 P.S. § 4005(a)(1) and (8)).
This section cited in 25 Pa. Code § 121.1 (relating to definitions); 25 Pa. Code § 129.96 (relating to applicability); 25 Pa. Code § 129.98 (relating to facility-wide or system-wide NOx emissions averaging plan general requirements); 25 Pa. Code § 129.99 (relating to alternative RACT proposal and petition for alternative compliance schedule); 25 Pa. Code § 129.100 (relating to compliance demonstration and recordkeeping requirements); and 25 Pa. Code § 129.112 (relating to presumptive RACT requirements, RACT emission limitations and petition for alternative compliance schedule).