Or. Admin. Code § 818-026-0065

Current through Register Vol. 63, No. 12, December 1, 2024
Section 818-026-0065 - [Effective 1/1/2025] Deep Sedation Permit

Deep sedation, moderate sedation, minimal sedation, and nitrous oxide sedation.

(1) The Board shall issue a Deep Sedation Permit to a licensee who holds a Class 3 Permit on or before July 1, 2010 who:
(a) Is a licensed dentist in Oregon; and
(b) In addition to a current BLS for Healthcare Providers certificate or its equivalent, maintains a current Advanced Cardiac Life Support (ACLS) certificate and/or a Pediatric Advanced Life Support (PALS) certificate, whichever is appropriate for the patient being sedated.
(2) The following facilities, equipment and drugs shall be on site and available for immediate use during the procedures and during recovery:
(a) An operating room large enough to adequately accommodate the patient on an operating table or in an operating chair and to allow an operating team of at least two individuals to freely move about the patient;
(b) An operating table or chair which permits the patient to be positioned so the operating team can maintain the patient's airway, quickly alter the patient's position in an emergency, and provide a firm platform for the administration of basic life support;
(c) A lighting system which permits evaluation of the patient's skin and mucosal color and a backup lighting system of sufficient intensity to permit completion of any operation underway in the event of a general power failure;
(d) Suction equipment which permits aspiration of the oral and pharyngeal cavities and a backup suction device which will function in the event of a general power failure;
(e) An oxygen delivery system with adequate full face mask and appropriate connectors that is capable of delivering high flow oxygen to the patient under positive pressure, together with an adequate backup system;
(f) A nitrous oxide delivery system with a fail-safe mechanism that will insure appropriate continuous oxygen delivery and a scavenger system;
(g) A recovery area that has available oxygen, adequate lighting, suction and electrical outlets. The recovery area can be the operating room;
(h) Sphygmomanometer, precordial/pretracheal stethoscope, capnograph, pulse oximeter, electrocardiograph monitor (ECG), automated external defibrillator (AED), oral and nasopharyngeal airways, laryngeal mask airways, intravenous fluid administration equipment; and
(i) Emergency drugs including, but not limited to: pharmacologic antagonists appropriate to the drugs used, vasopressors, corticosteroids, bronchodilators, antihistamines, antihypertensives and anticonvulsants.
(3) No permit holder shall have more than one person under deep sedation, moderate sedation, minimal sedation, or nitrous oxide sedation at the same time.
(4) During the administration of deep sedation, and at all times while the patient is under deep sedation, an anesthesia monitor, and one other person holding a current BLS for Healthcare Providers certificate or its equivalent, shall be present in the operatory, in addition to the dentist permit holder performing the dental procedures.
(5) Before inducing deep sedation, a dentist permit holder who induces deep sedation shall:
(a) Evaluate the patient and document, using the American Society of Anesthesiologists (ASA) Patient Physical Status Classifications, that the patient is an appropriate candidate for deep sedation;
(b) Give written preoperative and postoperative instructions to the patient or, when appropriate due to age or psychological status of the patient, the patient's guardian; and
(c) Obtain written informed consent from the patient or patient's guardian for the anesthesia. The obtaining of the informed consent shall be documented in the patient's record.
(6) A patient under deep sedation shall be visually monitored at all times, including the recovery phase. The dentist permit holder or anesthesia monitor shall monitor and record the patient's condition.
(7) Persons serving as anesthesia monitors for deep sedation in a dental office shall maintain current certification in BLS for Healthcare Providers Basic Life Support (BLS)/Cardio Pulmonary Resuscitation (CPR) training, or its equivalent, shall be trained and competent in monitoring patient vital signs, in the use of monitoring and emergency equipment appropriate for the level of sedation utilized. ("competent" means displaying special skill or knowledge derived from training and experience.)
(8) The patient shall be monitored as follows:
(a) Patients must have continuous monitoring using pulse oximetry, electrocardiograph monitors (ECG) and End-tidal CO2 monitors. The patient's heart rhythm shall be continuously monitored and the patient's blood pressure, heart rate, and respiration shall be recorded at regular intervals but at least every 5 minutes, and these recordings shall be documented in the patient record. The record must also include documentation of preoperative and postoperative vital signs, all medications administered with dosages, time intervals and route of administration. If this information cannot be obtained, the reasons shall be documented in the patient's record. A patient under deep sedation shall be continuously monitored;
(b) Once sedated, a patient shall remain in the operatory for the duration of treatment until criteria for transportation to recovery have been met.
(c) During the recovery phase, the patient must be monitored by an individual trained to monitor patients recovering from deep sedation.
(9) A dentist permit holder shall not release a patient who has undergone deep sedation except to the care of a responsible third party. When a reversal agent is administered, the dentist permit holder shall document justification for its use and how the recovery plan was altered.
(10) The dentist permit holder shall assess the patient's responsiveness using preoperative values as normal guidelines and discharge the patient only when the following criteria are met:
(a) Vital signs including blood pressure, pulse rate and respiratory rate are stable;
(b) The patient is alert and oriented to person, place and time as appropriate to age and preoperative psychological status;
(c) The patient can talk and respond coherently to verbal questioning;
(d) The patient can sit up unaided;
(e) The patient can ambulate with minimal assistance; and
(f) The patient does not have uncontrollable nausea or vomiting and has minimal dizziness.
(11) A discharge entry shall be made by the dentist permit holder in the patient's record indicating the patient's condition upon discharge and the name of the responsible party to whom the patient was discharged.
(12) Pursuant to OAR 818-042-0115 a Certified Anesthesia Dental Assistant, when directed by a dentist permit holder, may administer oral sedative agents calculated by a dentist permit holder or introduce additional anesthetic agents into an infusion line under the direct visual supervision of a dentist.
(13) Permit renewal. In order to renew a Deep Sedation Permit, the permit holder must provide documentation of a current BLS for Healthcare Providers certificate or its equivalent; a current Advanced Cardiac Life Support (ACLS) certificate and/or a current Pediatric Advanced Life Support (PALS) certificate; and must complete 14 hours of continuing education in one or more of the following areas every two years: sedation, physical evaluation, medical emergencies, monitoring and the use of monitoring equipment, or pharmacology of drugs and agents used in sedation. Training taken to maintain current ACLS and/or PALS certificates may be counted toward this requirement. Continuing education hours may be counted toward fulfilling the continuing education requirement set forth in OAR 818-021-0060.

Or. Admin. Code § 818-026-0065

OBD 1-2010, f. 6-22-10, cert. ef. 7-1-10; OBD 2-2011(Temp), f. 5-9-11, cert. ef. 6-1-11 thru 1-27-11; OBD 4-2011, f. & cert. ef. 11-15-11; OBD 1-2013, f. 5-15-13, cert. ef. 7-1-13; OBD 1-2014, f. 7-2-14, cert. ef. 8-1-14; OBD 4-2015, f. 9-8-15, cert. ef. 1/1/2016; OBD 2-2016, f. 11-2-16, cert. ef. 3/1/2017; OBD 2-2018, amend filed 10/04/2018, effective 1/1/2019; OBD 2-2019, amend filed 10/29/2019, effective 1/1/2020; OBD 2-2024, amend filed 10/28/2024, effective 1/1/2025

Publications: Publications referenced are available from the agency.

Statutory/Other Authority: ORS 679

Statutes/Other Implemented: ORS 679.250(7) & 679.250(10)