Or. Admin. Code § 690-210-0220

Current through Register Vol. 63, No. 11, November 1, 2024
Section 690-210-0220 - Plastic Casing Joints

All plastic casing joints shall be watertight. Either "bell" type, threaded, or coupling hubs are approved. Hub couplings shall be of material meeting the specifications for plastic casings as set forth in OAR 690-210-0210. Joints shall be made by solvent cement in accordance with manufacturer's directions. Newly assembled joints require careful handling until the initial set has taken place, which varies with the temperature and the pipe size. The recommended initial set times are from manufacturer's recommendations (See Table 210-4).

Or. Admin. Code § 690-210-0220

WRD 9-1978, f. 12-12-78, ef. 1-1-79; WRD 13-1986, f. 10-7-86, ef. 11-1-86, Renumbered from 690-061-0036; WRD 7-1988, f. & cert. ef. 6-29-88; WRD 8-1993, f. 12-14-93, cert. ef. 1-1-94; WRD 7-2001, f. & cert. ef. 11-15-01; WRD 5-2015, f. & cert. ef. 7/1/2015; WRD 5-2023, amend filed 06/22/2023, effective 7/1/2023

To view attachments referenced in rule text, click here to view rule.

Statutory/Other Authority: ORS 536.090, ORS 537.505-537.795, ORS 536.027, ORS 536.900 & ORS 537.992

Statutes/Other Implemented: ORS 536.090, ORS 537.505-537.795, ORS 536.900 & ORS 537.992