Or. Admin. Code § 690-210-0180

Current through Register Vol. 63, No. 11, November 1, 2024
Section 690-210-0180 - Additional Standards for Driven or Jetted Wells

All drive point wells or jetted wells shall have nonperforated, watertight casing meeting the minimum specifications shown in Table 210-1 and extending a minimum distance of 18 feet below land surface. Drive casing greater than 3-1/2 inches shall comply with the minimum specifications in OAR 690-210-0190. An upper drillhole at least four inches greater in nominal diameter than the permanent casing shall extend at least 18 feet below land surface. The annular space shall be filled with grout. If temporary casing is used during construction, it must be removed during placement of the grout. (See Figure 210-10.)

Or. Admin. Code § 690-210-0180

WRD 9-1978, f. 12-12-78, ef. 1-1-79; WRD 13-1986, f. 10-7-86, ef. 11-1-86, Renumbered from 690-061-0186 & 690-061-0191; WRD 7-1988, f. & cert. ef. 6-29-88; WRD 8-1993, f. 12-14-93, cert. ef. 1-1-94; WRD 7-2001, f. & cert. ef. 11-15-01; WRD 5-2023, amend filed 06/22/2023, effective 7/1/2023

To view attachments referenced in rule text, click here to view rule.

Statutory/Other Authority: ORS 536.090, ORS 537.505-537.795, ORS 536.027, ORS 536.900 & ORS 537.992

Statutes/Other Implemented: ORS 536.090, ORS 537.505-537.795, ORS 536.900 & ORS 537.992