Section 252:641-12-3 - Shallow extended subsurface absorption fields
(a)Location. All shallow extended subsurface absorption fields shall be:
(1) located in the identified dispersal site; and
(2) installed more than five feet (5') from the septic tank or aerobic treatment unit.
(b)Fall. Unless a pump is utilized, there shall be a minimum fall of two inches (2") from the bottom of the outlet of the septic tank to the:
(1) highest point of the storage media in the shallow extended subsurface absorption field; or
(2) highest point of the permeable sidewall of a manufactured media system used in the shallow extended subsurface absorption field.
(c)Minimum linear length. All shallow extended subsurface absorption fields must meet the minimum length requirements set forth in Appendix H, Figures 7 and 8. If perforated pipe is used between distribution structures and installed in accordance with the trench requirements of this Section, it may be counted as part of the overall required length of the shallow extended subsurface absorption field.
(d)Trench length limitation. Shallow extended subsurface absorption fields shall be constructed so that no sewage flows through more than a total of one hundred fifty linear feet (150') of perforated pipe or manufactured media system in any given path.
(e)Trench spacing. The trenches in a shallow extended subsurface absorption field shall be spaced at least eight feet (8') apart, center to center.
(f)Trench width. All trenches in a shallow extended subsurface absorption field shall be twenty-four inches (24") wide.
(g)Trench depth. Each trench in a shallow extended subsurface absorption field shall have a uniform depth of at least fourteen inches (14"), and no more than seventeen inches (17"). The bottom of the trenches shall be level.
(h)Dispersal and storage. Each trench in a shallow extended subsurface absorption field shall contain a zone for the dispersal and storage of effluent with a total depth of at least six inches (6"), comprised of either perforated pipe and storage media or a manufactured media system.
(i)Retention structure. Retention structures must be used between trenches of different elevations in shallow extended subsurface absorption fields. When a retention structure is used:
(1) the bottom of the outlet pipe of a retention structure or the bottom of the outlet pipe of a manufactured media system being used as a retention structure shall be six inches (6") above the trench bottom; and
(2) the line from the outlet of a retention structure to the next distribution point shall be constructed of solid pipe and shall be backfilled with compacted native soil.
(j)Backfill. For shallow extended subsurface absorption fields:
(1) the depth of the backfill shall be consistent and shall not vary more than four inches (4"); and
(2) the backfill shall consist of at least eight inches (8") of topsoil.