Okla. Admin. Code § 252:517-3-43

Current through Vol. 41, No. 19, June 17, 2024
Section 252:517-3-43 - Fill cross section map
(a)Required map. The permit application shall include a fill cross section map.
(b)Required details. A grid system shall be established and typical cross sections plotted along the principal axis and along the minor axis.
(1) A cross section locator map shall show the grid system superimposed over the site plan with each cross-section labeled. This drawing may be at any convenient scale and labeled accordingly.
(2) Cross section drawings shall depict the elevation(s) of the top of any dikes or levees, the final cover, wastes, ground surface, the top of liner, the bottom of excavations, the side slopes of trenches and fill areas, groundwater monitor wells, gas wells or vents, and recorded initial and static water levels.
(3) The scale shall be 1:600 (1 inch = 50 feet) horizontal and 1:60 (1 inch = 5 feet) vertical.
(4) Soil borings may also be shown on the profile.

Okla. Admin. Code § 252:517-3-43

Adopted by Oklahoma Register, Volume 33, Issue 24, September 1, 2016, eff. 9/15/2016