Section 252:100-37-42 - Permit-by-rule requirements(a) An owner or operator shall submit annual emission inventory reports and meet the requirements of 252:100-37-5, regarding operation and maintenance, and 252:100-37-38, regarding pumps and compressors.(b) No owner or operator shall build or install a new stationary VOC storage vessel with a capacity of 400 gal (1.5 m3) or greater unless it is equipped with a permanent submerged fill pipe as defined in 252:100-37-2.(c) No owner or operator shall build or install a stationary VOC loading facility unless each loading pipe is equipped with a system for submerged filling of tank trucks or trailers which is installed and operated to maintain a 97 percent submergence factor.(d) The owner or operator of a vessel with a storage capacity greater than 10,567 gal (40 m3) shall maintain records on site of the dimensions of the storage vessel and an analysis showing the capacity.Okla. Admin. Code § 252:100-37-42
Added at 16 Ok Reg 1767, eff 6-11-99