Section 252:100-24-7 - Permit by rule
(a)Applicability. Any new or existing source may be constructed or operated under this section if it meets the requirements of 252:100-7-60(a), (b), and (c) and has the Standard Industrial Classification (SIC) code 5153, Grain and Field Beans.
(b)Requirements.
(1) In addition to the requirements in 252:100-7-60(a), (b), and (c), an owner or operator of a facility subject to this section shall comply with all of the requirements of this Subchapter, with the exception of 252:100-24-5(a) and (b).
(2) The total annual emissions of PM-10 shall be calculated using the equation provided in Appendix L, which was derived from AP-42 9.9.1, Grain Elevators and Processes.
(3) For grain storage elevators located at any wheat flour mill, wet corn mill, dry corn mill, rice mill or soybean oil extraction plant, with a permanent grain storage capacity of 35,200 m3, or grain terminal elevators with a permanent storage capacity of more than 88,100 m3, which have commenced construction, modification, or reconstruction after August 3, 1978, the requirements of 40 CFR, Part 60, Subpart DD are also applicable.