Lighting of no less than ten lumens shall be provided at the tunnel and shaft headings and no less than five lumens elsewhere in the tunnel or shaft where employees are required to work.
Protective clothing or equipment shall be worn as specified in rule 4123:1-3-03 of the Administrative Code.
Employees exposed to a time-weighted average (TWA) of noise levels of ninety or more decibels (>90dBA TWA) slow response shall be provided with approved hearing protection.
Oil-filled transformers shall not be used underground unless they are located in a fire-resistant enclosure and surrounded by a dike to contain contents of the transformers in event of a rupture.
Caissons shall be substantially braced before loading with concrete or other weight.
When two or more caissons are sunk together, employees shall be removed from adjacent caissons during concreting operations.
All outside air locks shall be provided with a platform no less than forty-two inches wide, and such platform shall be provided with a standard guard railing and toeboard.
All caissons in compressed air environments in which there are fifteen or more employees, or are ten feet or more in diameter, shall have two locks, one of which shall be used as a manlock. It shall be the duty of one or more trained employees to be in charge of and operate said manlock and any associated man shafts.
The bottom of the lowest door opening of locks shall be no less than three feet above water level.
When work is in progress which requires employees to work in compressed air, there shall be present a representative of the employer, who is thoroughly trained and experienced in compressed air techniques.
Effective and reliable means of communication, such as bells, whistles, or telephones, shall be maintained at all times between all the following locations:
"Time of Decompression for this Lock"
................ pounds to ................ pounds in ..................... minutes.
................ pounds to ................ pounds in ..................... minutes.
(Signed by) ______________________________________
(Superintendent)
This form shall be posted in the manlock at all times.
Ohio Admin. Code 4123:1-3-16
Five Year Review (FYR) Dates: 10/29/2019 and 01/01/2025
Promulgated Under: 119.03
Statutory Authority: 4121.12, 4121.121, 4121.13, Const. Art. II, Sec. 35
Rule Amplifies: 4121.47
Prior Effective Dates: 04/01/1968, 11/01/1979, 04/01/1999, 01/01/2011