(A) Reporting requirements.
(1) Systems shall report sampling schedules in accordance with paragraph (I) of rule 3745-81-65 of the Administrative Code and source water monitoring results in accordance with paragraph (A) of rule 3745-81-66 of the Administrative Code unless they notify the director that they will not conduct source water monitoring due to meeting the criteria of paragraph (D) of rule 3745-81-65 of the Administrative Code.
(2) Systems shall report their Cryptosporidium bin classification as described in paragraphs (A) to (D) of rule 3745-81-67 of the Administrative Code.
(3) Systems shall report disinfection profiles and benchmarks to the director as described in paragraph (E) of rule 3745-81-72 of the Administrative Code prior to making a significant change in disinfection practice.
(4) Systems shall report to the director in accordance with the following table for any microbial toolbox options used to comply with treatment requirements in accordance with paragraph (E) of rule 3745-81-67 of the Administrative Code. Alternatively, the director may approve a system to certify operation within required parameters for treatment credit rather than reporting monthly operational data for toolbox options.

Click to view image

Click to view image

Click to view image

Click to view image

Click to view image

Click to view image

(B) Recordkeeping requirements.
(1) Systems shall keep results from the initial round of source water monitoring in accordance with paragraph (A) of rule 3745-81-65 of the Administrative Code and the second round of source water monitoring in accordance with paragraph (B) of rule 3745-81-65 of the Administrative Code until three years after bin classification in accordance with paragraphs (A) to (D) of rule 3745-81-67fortheparticularround of monitoring.
(2) Systems shall keep any notification to the director that they will not conduct source water monitoring due to meeting the criteria of paragraph (D) of rule 374581-65 of the Administrative Code for three years.
(3) Systems shall keep the results of treatment monitoring associated with microbial toolbox options in accordance with paragraphs (B) to (N) of rule 3745-81-68 of the Administrative Code, as applicable, for three years.

Ohio Admin. Code 3745-81-69

Five Year Review (FYR) Dates: 10/5/2021 and 01/01/2026
Promulgated Under: 119.03
Statutory Authority: 6109.04
Rule Amplifies: 6109.04
Prior Effective Dates: 01/08/2010
Effective: 1/8/2010
R.C. 119.032 review dates: 01/08/2015
Promulgated Under: 119.03
Statutory Authority: 6109.04
Rule Amplifies: 6109.03, 6109.04
Five Year Review (FYR) Dates: 01/29/2015 and 01/29/2020
Promulgated Under: 119.03
Statutory Authority: 6109.04
Rule Amplifies: 6109.04