[Comment: For dates of non-regulatory government publications, publications of recognized organizations and associations, federal rules, and federal statutory provisions referenced in this rule, see the "Incorporation by Reference" section at the end of this rule.]
Hg= 2.5 H
Where: Hg = good engineering practice stack height, measured from the ground-level elevation at the base of the stack; and
H = height of nearby structure(s) measured from the ground-level elevation at the base of the stack;
Provided the owner or operator produces evidence that this equation was actually relied on in establishing an emission limitation; or
Hg= H + 1.5 L
Where: Hg= good engineering practice stack height, measured from the ground-level elevation at the base of the stack;
H = height of nearby structure(s) measured from the ground-level elevation at the base of the stack; and
L = height or projected width, whichever is less, of nearby structure(s);
Provided that the director may require the use of a field study or fluid model to verify GEP stack height for the source; or
Ohio Admin. Code 3745-16-01
R.C. 119.032 review dates: Exempt
Promulgated Under: 119.03
Statutory Authority: 3704.03(E)
Rule Amplifies: 3704.03(A), 3704.03(E)
Prior Effective Dates: 3/5/86