Ohio Admin. Code 3701:1-48-20

Current through all regulations passed and filed through October 28, 2024
Section 3701:1-48-20 - Radiation surveys

The licensee shall:

(A) Conduct surveys with a calibrated and operable radiation survey instrument that meets the requirements of rule 3701:1-48-08 of the Administrative Code.
(B) Using a survey instrument meeting the requirements of paragraph (A) of this rule, conduct a survey of the radiographic exposure device and the guide tube after each exposure when approaching the device or the guide tube. The survey must determine that the sealed source has returned to its shielded position before exchanging films, repositioning the exposure head, or dismantling equipment.
(C) Conduct a survey of the radiographic exposure device with a calibrated radiation survey instrument any time the source is exchanged and whenever a radiographic exposure device is placed in a storage area (as defined in rule 3701:1-48-01 of the Administrative Code), to ensure that the sealed source is in its shielded position.
(D) Maintain records in accordance with paragraph (L) of rule 3701:1-48-23 of the Administrative Code.

Ohio Admin. Code 3701:1-48-20

Five Year Review (FYR) Dates: 4/7/2022 and 04/07/2027
Promulgated Under: 119.03
Statutory Authority: 3748.04
Rule Amplifies: 3748.04
Prior Effective Dates: 10/20/2002
Five Year Review (FYR) Dates: 04/04/2016 and 04/01/2021
Promulgated Under: 119.03
Statutory Authority: 3748.04
Rule Amplifies: 3748.06, 3748.07
Prior Effective Dates: 10/20/2002, 3/22/07