N.D. Admin. Code 69-10-02-10

Current through Supplement No. 393, July, 2024
Section 69-10-02-10 - Indicating and printing elements

A beam-type or dial-type indicating element must be installed in a level and plumb position, mounted on concrete piers, or on a concrete slab, and fastened securely to the concrete walls or neck of the scale pit. These mechanical indicating element foundations must be independent of the scalehouse floor, weighing room, or other similar structures. The installation of a dial must allow for adequate clearance for service between the cabinet of the dial and the wall. Motor truck, motor truck dump, railroad track, and livestock scales installed after July 1, 1973, and used in commerce, must be equipped with a ticket printing device with a copy of the printed receipt issued to the customer at the time of the delivery. Notwithstanding the above, for a scale installed prior to July 1, 1973, equipped with any type of ticket printing capability, its operator must use that ticket printing capability for all sales, with a copy of the printed ticket to be issued to the customer at the time of the delivery. A shoulder or stop must be provided on each weighbeam bar to prevent the poise from traveling and remaining behind the zero graduation. An indicating or printing element must be adequately protected against environmental damage.

N.D. Admin Code 69-10-02-10

Amended effective August 1,1993; September 1, 1994; February 1,1996; July 1, 1997.

General Authority: NDCC 64-02-03

Law Implemented: NDCC 64-02-02, 64-02-13