N.D. Admin. Code 33-24-05-476

Current through Supplement No. 393, July, 2024
Section 33-24-05-476 - Design and operating standards
1. All containment buildings must comply with the following design standards:
a. The containment building must be completely enclosed with a floor, walls, and a roof to prevent exposure to the elements (for example, precipitation, wind, run-on) and to assure containment of managed wastes.
b. The floor and containment walls of the unit, including the secondary containment system if required under subsection 2, must be designed and constructed of materials of sufficient strength and thickness to support themselves, the waste contents, and any personnel and heavy equipment that operate within the unit, and to prevent failure due to pressure gradients, settlement, compression, or uplift, physical contact with the hazardous wastes to which they are exposed; climatic conditions; and the stresses of daily operation, including the movement of heavy equipment within the unit and contact of such equipment with containment walls. The unit must be designed so that it has sufficient structural strength to prevent collapse or other failure. All surfaces to be in contact with hazardous wastes must be chemically compatible with those wastes. The department will consider standards established by professional organizations generally recognized by the industry such as the American concrete institute or the American society of testing materials in judging the structural integrity requirements of this subsection. If appropriate to the nature of the waste management operation to take place in the unit, an exception to the structural strength requirement may be made for lightweight doors and windows that meet these criteria:
(1) They provide an effective barrier against fugitive dust emissions under paragraph 4 of subdivision a of subsection 3; and
(2) The unit is designed and operated in a fashion that assures that wastes will not actually come in contact with these openings.
c. Incompatible hazardous wastes or treatment reagents must not be placed in the unit or its secondary containment system if they could cause the unit or secondary containment system to leak, corrode, or otherwise fail.
d. A containment building must have a primary barrier designed to withstand the movement of personnel, waste, and handling equipment in the unit during the operating life of the unit and appropriate for the physical and chemical characteristics of the waste to be managed.
2. For a containment building used to manage hazardous wastes containing free liquids or treated with free liquids (the presence of which is determined by the paint filter test, a visual examination, or other appropriate means), the owner or operator must include:
a. A primary barrier designed and constructed of materials to prevent the migration of hazardous constituents into the barrier (for example, a geomembrane covered by a concrete wear surface).
b. A liquid collection and removal system to minimize the accumulation of liquid on the primary barrier of the containment building:
(1) The primary barrier must be sloped to drain liquids to the associated collection system; and
(2) Liquids and waste must be collected and removed to minimize hydraulic head on the containment system at the earliest practicable time.
c. A secondary containment system including a secondary barrier designed and constructed to prevent migration of hazardous constituents into the barrier, and a leak detection system that is capable of detecting failure of the primary barrier and collecting accumulated hazardous wastes and liquids at the earliest practicable time.
(1) The requirements of the leak detection component of the secondary containment system are satisfied by installation of a system that is, at a minimum:
(a) Constructed with a bottom slope of one percent or more; and
(b) Constructed of a granular drainage material with a hydraulic conductivity of 1x10-2 centimeters per second or more and a thickness of twelve inches [30.5 centimeters] or more, or constructed of synthetic or geonet drain materials with a transmissivity of 3x10-5 square meters per second.
(2) If treatment is to be conducted in the building, an area in which such treatment will be conducted must be designed to prevent the release of liquids, wet materials, or liquid aerosols to other portions of the building.
(3) The secondary containment system must be constructed of materials that are chemically resistant to the waste and liquids managed in the containment building and of sufficient strength and thickness to prevent collapse under the pressure exerted by overlaying materials and by any equipment used in the containment building. (Containment buildings can serve as secondary containment systems for tanks placed within the building under certain conditions. A containment building can serve as an external liner system for a tank, provided it meets the requirements of subdivision a of subsection 5 of section 33-24-05-106. In addition, the containment building must meet the requirements of subsection 2 of section 33-24-05-106 and subdivisions a and b of subsection 3 of section 33-24-05-106 to be considered an acceptable secondary containment system for a tank.)
d. For existing units other than ninety-day generator units, the department may delay the secondary containment requirement for up to two years, based on a demonstration by the owner or operator that the unit substantially meets the standards of sections 33-24-05-475 through 33-24-05-500. In making this demonstration, the owner or operator must:
(1) Provide written notice to the department of the request by November 16, 1992. This notification must describe the unit and its operating practices with specific reference to the performance of existing containment systems, and specific plans for retrofitting the unit with secondary containment;
(2) Respond to any comments from the department on these plans within thirty days; and
(3) Fulfill the terms of the revised plans, if such plans are approved by the department.
3. Owners or operators of all containment buildings must:
a. Use controls and practices to ensure containment of the hazardous waste within the unit; and, at a minimum:
(1) Maintain the primary barrier to be free of significant cracks, gaps, corrosion, or other deterioration that could cause hazardous waste to be released from the primary barrier;
(2) Maintain the level of the stored or treated hazardous waste within the containment walls of the unit so that the height of any containment wall is not exceeded;
(3) Take measures to prevent the tracking of hazardous waste out of the unit by personnel or by equipment used in handling the waste. An area must be designated to decontaminate equipment and any rinsate must be collected and properly managed; and
(4) Take measures to control fugitive dust emissions such that any openings (doors, windows, vents, cracks, etc.) exhibit no visible emissions (see 40 CFR part 60, appendix A, method 22 Visual Determination of Fugitive Emissions from Material Sources and Smoke Emissions from Flares). In addition, all associated particulate collection devices (for example, fabric filter, electrostatic precipitator) must be operated and maintained with sound air pollution control practices (see 40 CFR part 60 subpart 292 for guidance). This state of no visible emissions must be maintained effectively at all times during routine operating and maintenance conditions, including when vehicles and personnel are entering and exiting the unit.
b. Obtain and keep onsite a certification by a qualified professional engineer that the containment building design meets the requirements of subsections 1, 2, and 3.
c. Throughout the active life of the containment building, if the owner or operator detects a condition that could lead to or has caused a release of hazardous waste, the owner or operator must repair the condition promptly, in accordance with the following procedures.
(1) Upon detection of a condition that has led to a release of hazardous waste (for example, upon detection of leakage from the primary barrier) the owner or operator must:
(a) Enter a record of the discovery in the facility operating record;
(b) Immediately remove the portion of the containment building affected by the condition from service;
(c) Determine what steps must be taken to repair the containment building, remove any leakage from the secondary collection system, and establish a schedule for accomplishing the cleanup and repairs; and
(d) Within seven days after the discovery of the condition, notify the department of the condition, and within fourteen working days, provide a written notice to the department with a description of the steps taken to repair the containment building, and the schedule for accomplishing the work.
(2) The department will review the information submitted, make a determination regarding whether the containment building must be removed from service completely or partially until repairs and cleanup are complete, and notify the owner or operator of the determination and the underlying rationale in writing.
(3) Upon completing all repairs and cleanup the owner or operator must notify the department in writing and provide a verification, signed by a qualified, registered professional engineer, that the repairs and cleanup have been completed according to the written plan submitted in accordance with subparagraph d of paragraph 1 of subdivision c of subsection 3.
d. Inspect and record in the facility's operating record, at least once every seven days, data gathered from monitoring and leak detection equipment as well as the containment building and the area immediately surrounding the containment building to detect signs of releases of hazardous waste.
4. For containment buildings that contain both areas with and without secondary containment, the owner or operator must:
a. Design and operate each area in accordance with the requirements enumerated in subsections 1, 2, and 3;
b. Take measures to prevent the release of liquids or wet materials into areas without secondary containment; and
c. Maintain in the facility's operating log a written description of the operating procedures used to maintain the integrity of areas without secondary containment.
5. Notwithstanding any other provision of sections 33-24-05-475 through 33-24-05-500, the department may waive requirements for secondary containment for a permitted containment building where the owner or operator demonstrates that the only free liquids in the unit are limited amounts of dust suppression liquids required to meet occupational health and safety requirements, and where containment of managed wastes and liquids can be assured without a secondary containment system.

N.D. Admin Code 33-24-05-476

Effective January 1, 1994; amended effective July 1, 1997; December 1, 2003.
Amended by Administrative Rules Supplement 2016-359, January 2016, effective 1/1/2016.

General Authority: NDCC 23-20.3-03

Law Implemented: NDCC 23-20.3-03, 23-20.3-04