The treatment standard for many characteristic wastes is stated in the 33-24-05-280 Table of Treatment Standards as "Deactivation and meet UTS." The environmental protection agency has determined that many technologies, when used alone or in combination, can achieve the deactivation portion of the treatment standard. Characteristic wastes that are not managed in a facility regulated by the Clean Water Act or in a Clean Water Act-equivalent facility, and that also contain underlying hazardous constituents (see subsection 10 of section 33-24-05-251) must be treated not only by a "deactivating" technology to remove the characteristic, but also to achieve the universal treatment standards for underlying hazardous constituents. The following appendix presents a partial list of technologies, utilizing the five letter technology codes established in Table 1 of section 33-24-05-282, that may be useful in meeting the treatment standard. Use of these specific technologies is not mandatory and does not preclude direct reuse, recovery, or the use or any combination thereof, of other pretreatment technologies, provided deactivation is achieved and underlying hazardous constituents are treated to achieve the universal treatment standards.
Waste Code/Subcategory | Nonwastewaters | Wastewaters |
D001 Ignitable Liquids based on 33-24-02-11.1.a.-Low TOC Nonwastewater Subcategory (containing 1% to <10% TOC). | RORGS .......... INCIN .......... WETOX .......... CHOXD .......... BIODG .......... | n.a. |
D001 Ignitable Liquids based on 33-24-02-11.1.a.-Ignitable Wastewater Subcategory(containing <1% TOC). | n.a ........... | RORGS INCIN WETOX CHOXD BIODG |
D001 Compressed Gases based on 33-24-02-11.1.c .......... | RCGAS .......... INCIN .......... FSUBS .......... ADGAS fb. INCIN .......... ADGAS fb. (CHOXD; or CHRED). | n.a. |
D001 Ignitable Reactives based on 33-24-02-11.1.b .......... | WTRRX .......... CHOXD .......... CHRED .......... STABL .......... INCIN .......... | n.a. |
D001 Ignitable Oxidizers based on 33-24-02-11.1.d .......... | CHRED .......... INCIN .......... | CHRED INCIN |
D002 Acid Subcategory based on 33-24-02-12.1.a. with pH less than or equal to 2 | RCORR .......... NEUTR .......... INCIN .......... | NEUTR INCIN |
D002 Alkaline Subcategory based on 33-24-02-12.1.a. with pH greater than or equal to 12.5 | NEUTR .......... INCIN .......... | NEUTR INCIN |
D002 Other Corrosives based on 33-24-02-12.1.b .......... | CHOXD .......... CHRED .......... INCIN .......... STABL .......... | CHOXD CHRED INCIN |
D003 Water Reactives based on 33-24-02-13.1.b., c., and d .......... | INCIN .......... WTRRX | n.a. |
CHOXD .......... CHRED .......... | ||
D003 Reactive Sulfides based on 33-24-02-13.1.e .......... | CHOXD .......... CHRED .......... INCIN .......... STABL .......... | CHOXD CHRED BIODG INCIN |
D003 Explosives based on 33-24-02-13.1.f., g., and h .......... | INCIN .......... CHOXD .......... CHRED .......... | INCIN CHOXD CHRED BIODG CARBN |
D003 Other Reactives based on 33-24-02-13.1.a .......... | INCIN .......... CHOXD .......... CHRED .......... | INCIN CHOXD CHRED BIODG CARBN |
K044 Wastewater treatment sludges from the manufacturing and processing of explosives. | CHOXD .......... CHRED .......... INCIN .......... | CHOXD CHRED BIODG CARBN INCIN |
K045 Spent carbon from the treatment of wastewaters containing explosives. | CHOXD .......... CHRED .......... INCIN .......... | CHOXD CHRED BIODG CARBN INCIN |
K047 Pink/red water from TNT operations .......... | CHOXD .......... CHRED .......... INCIN .......... | CHOXD CHRED BIODG CARBN INCIN |
Note: "n.a." stands for "not applicable;" "fb." stands for "followed by."