Section 02D .2604 - NUMBER OF TEST POINTS(a) Method 1 of Appendix A to 40 CFR Part 60 shall be used to select a suitable site and the appropriate number of test points for the following situations: (2) volatile organic compounds testing;(3) velocity and volume flow rate measurements;(4) testing for acid mist or other pollutants occurring in liquid droplet form;(5) sampling for which velocity and volume flow rate measurements are necessary for computing final test results; or(b) Method 1 of Appendix A to 40 CFR Part 60 shall be used as written with the following clarifications:(1) Testing installations with multiple ducts may be accomplished by testing the discharge stacks to which the ducts exhaust. If the multiple ducts are individually tested, then Method 1 shall be applied to each duct individually.(2) If test ports in a duct are less than two diameters downstream or less than one-half diameter upstream from any disturbance, such as a fan, elbow, change in diameter, or other physical feature disturbing the gas flow, the acceptability of the test location shall be determined by the Director before the test and after a review of technical and economic factors.15A N.C. Admin. Code 02D .2604