10A N.C. Admin. Code 14J.1218

Current through Register Vol. 39, No. 9, November 1, 2024
Section 14J .1218 - PLUMBING SYSTEMS
(a) A jail shall have a hot water supply for lavatories and showers designed to meet the needs of the number of inmates confined in the jail, as determined by the governing body. The hot water temperature at lavatories and showers used by inmates shall be maintained at a minimum of 100 degrees F (38 degrees C) and shall not exceed 116 degrees F (46.7 degrees C).
(b) A jail shall not locate the following valves of the water supply system in rooms or areas accessible by inmates:
(1) a shut-off valve for a supply branch line serving plumbing fixtures;
(2) a shut-off valve for a riser pipe serving plumbing fixtures; and
(3) a shut-off valve to a plumbing fixture.
(c) The shut-off valves listed in Paragraph (b) of this Rule shall be accessible to officers.

10A N.C. Admin. Code 14J .1218

Authority G.S. 153A-221;
Eff. June 1, 1990;
Amended Eff. June 1, 1992;
Readopted Eff. September 4, 2020.
Authority G.S. 143B-153; 153A-221;
Eff. June 1, 1990;
Amended Eff. June 1, 1992.
Readopted by North Carolina Register Volume 33, Issue 23, June 3, 2019 Eff. 9/4/2020.