Table 1: Setback Requirements for Wind Turbine Towers
Structure type | Wind Turbine Towers setback* |
Substation | 1.5 times |
Any Above-ground Bulk Electric System** | 1.5 times |
Gas Wells (unless waived by landowner and gas well operator) | 1.1 times |
Public Roads | 1.1 times |
Property Lines | 1.1 times |
Non-participating, non-residential Structures | 1.5 times |
Non-participating Residences | 2 times |
*1.0 times Wind Turbine Towers setback is equal to the Total Height of the Wind Facility (at the maximum blade tip height). **Operated at 100 kV or higher, and as defined by North American Electric Reliability Corporation Bulk Electric System Definition Reference Document Version 3, August 2018 (see section 1100-15.1(e)(1)(i) of this Part) |
Table 2: Setback Requirements for Solar Facility Components
Setback Type | Solar Facility Setback |
Non-participating residential property lines | 100 feet |
Centerline of Public Roads | 50 feet |
Non-participating property lines (non-residential) | 50 feet |
Non-participating occupied residences | 250 feet |
N.Y. Comp. Codes R. & Regs. Tit. 16 §§ 1100-2.6