Current through Register Vol. 46, No. 45, November 2, 2024
Section 753-4.8 - Uniform identification lettersAll staking and marking utilized for the location of underground facilities shall contain letter designations which will clearly identify the type of underground facility so staked or marked. Such letters shall comply with the following code:
(a) C--communication facilities (other than telephone service).(c) CTV--cable television.(g) HPW--high-pressure water (100 psig or more).(i) PP--petroleum products (naphtha, Gasoline, kerosine and similar products).(l) T--telephone company services.(m) TC--traffic control signals.(o) O--all other facilities.N.Y. Comp. Codes R. & Regs. Tit. 16 §§ 753-4.8