TABLE I
STEEPEST ALLOWABLE UNBRACED SLOPES
Depth of Excavation | ||
Type of Soil or Rock | 5 to 10 ft. | Over 10 ft. |
Stiff cohesive soil | 11/2 vertical on 1 horizontal | 1 vertical on 1 horizontal (trench) 1 1/2 vertical on 1 horizontal (area) |
Noncohesive soil | 1 vertical on 1 horizontal 1 vertical on 1 1/2 horizontal (when subject to vibrations) | 1 vertical on 1 horizontal 1 vertical on 1 1/2 horizontal (when subject to vibrations) |
Soft cohesive or wet flowing soil | 1 vertical on 1 horizontal 1 vertical on 11/2 horizontal (when subject to vibrations) | 1 vertical on 11/2 horizontal (trench) 1 vertical on 1 horizontal (area) 1 vertical on 1 1/2 horizontal (when subject to vibrations) |
Stable rock | Vertical sides permitted | Vertical sides permitted |
Unstable rock | 11/2 vertical on 1 horizontal | 11/2 vertical on 1 horizontal |
Notes: The slopes given in Table I are the steepest allowable. Conditions may occur requiring the use of flatter slopes to prevent slope failure and subsidence of adjacent areas. A slope shall start from the bottom of each side of an excavation or where the lower portions of such sides consist of stable rock from the top of such rock.
N.Y. Comp. Codes R. & Regs. Tit. 12 §§ 23-4.2