N.M. Admin. Code § 20.2.50.118

Current through Register Vol. 35, No. 21, November 5, 2024
Section 20.2.50.118 - GLYCOL DEHYDRATORS
A.Applicability: Glycol dehydrators with a PTE equal to or greater than two tpy of VOC and located at well sites, tank batteries, gathering and boosting stations, natural gas processing plants, and transmission compressor stations are subject to the requirements of 20.2.50.118 NMAC.
B.Emission standards:
(1) Existing glycol dehydrators with a PTE equal to or greater than two tpy of VOC shall achieve a minimum combined capture and control efficiency of ninety-five percent of VOC emissions from the still vent and flash tank (if present) no later than two years after the effective date of this Part. If a combustion control device is used, the combustion control device shall have a minimum design combustion efficiency of ninety-eight percent.
(2) New glycol dehydrators with a PTE equal to or greater than two tpy of VOC shall achieve a minimum combined capture and control efficiency of ninety-five percent of VOC emissions from the still vent and flash tank (if present) upon startup. If a combustion control device is used, the combustion control device shall have a minimum design combustion efficiency of ninety-eight percent.
(3) The owner or operator of a glycol dehydrator shall comply with the following requirements:
(a) the still vent and flash tank emissions shall be routed at all times to the reboiler firebox, condenser, combustion control device, fuel cell, to a process point that either recycles or recompresses the VOC emissions or uses the emissions as fuel, or to a VRU that reinjects the VOC emissions back into the process stream or natural gas pipeline;
(b) if a VRU is used, it shall consist of a closed loop system of seals, ducts, and a compressor that reinjects the vapor into the process or the natural gas pipeline. The VRU shall be operational at least ninety-five percent of the time the facility is in operation, resulting in a minimum combined capture and control efficiency of ninety-five percent, which shall supersede any inconsistent requirements in 20.2.50.115 NMAC. The VRU shall be installed, operated, and maintained according to the manufacturer's specifications; and
(c) the still vent and flash tank emissions shall not be vented directly to the atmosphere during normal operation.
(4) An owner or operator complying with the requirements in Subsection B of 20.2.50.118 NMAC through use of a control device shall comply with the requirements in 20.2.50.115 NMAC.
(5) The requirements of Subsection B of 20.2.50.118 NMAC cease to apply when the actual annual VOC emissions from a new or existing glycol dehydrator are less than two tpy of VOC.
C.Monitoring requirements:
(1) The owner or operator of a glycol dehydrator shall conduct an annual extended gas analysis on the dehydrator inlet gas and calculate the uncontrolled and controlled VOC emissions in tpy.
(2) The owner or operator of a glycol dehydrator shall inspect the glycol dehydrator, including the reboiler and regenerator, and the control device or process the emissions are being routed, semi-annually to ensure it is operating as initially designed and in accordance with the manufacturer recommended operation and maintenance schedule.
(3) Prior to any monitoring event, the owner or operator shall date and time stamp the event, and the monitoring data entry shall be made in accordance with the requirements of this Part.
(4) An owner or operator complying with the requirements in Subsection B of 20.2.50.118 NMAC through the use of a control device shall comply with the monitoring requirements in 20.2.50.115 NMAC.
(5) Owners and operators shall comply with the monitoring requirements in 20.2.50.112 NMAC.
D.Recordkeeping requirements:
(1) The owner or operator of a glycol dehydrator shall maintain a record of the following:
(a) unique identification number and dehydrator location (latitude and longitude);
(b) glycol circulation rate, monthly natural gas throughput, and the date of the most recent throughput measurement;
(c) data and methodology used to estimate the PTE of VOC (must be a department approved calculation methodology);
(d) controlled and uncontrolled VOC emissions in tpy;
(e) type, make, model, and unique identification number of the control device or process the emissions are being routed;
(f) time and date stamp, including GPS of the location, of any monitoring;
(g) results of any equipment inspection, including maintenance or repair activities required to bring the glycol dehydrator into compliance; and
(h) a copy of the glycol dehydrator manufacturer specifications.
(2) An owner or operator complying with the requirements in Paragraph (1) or (2) of Subsection B of 20.2.50.118 NMAC through use of a control device as defined in this Part shall comply with the recordkeeping requirements in 20.2.50.115 NMAC.
(3) The owner or operator shall comply with the recordkeeping requirements in 20.2.50.112 NMAC.
E.Reporting requirements: The owner or operator shall comply with the reporting requirements in 20.2.50.112 NMAC.

N.M. Admin. Code § 20.2.50.118

Adopted by New Mexico Register, Volume XXXIII, Issue 14, July 26, 2022, eff. 8/5/2022