Q is the volume of sanitary sewage, determined as prescribed in 7:9A-7.4, in gallons per day, multiplied by a unit conversion factor of 1 ft[LESS THAN]3[GREATER THAN]/7.48 gallons.
L is the total length of the disposal field, in feet, measured parallel to the topographic contour.
K is the horizontal saturated permeability above the restrictive horizon, in inches per hour, determined as prescribed in 7:9A-6.5 or 6.6, multiplied by unit conversion factors of (1 foot/12 inches) and (24 hours/1 day).
I is the slope, in feet/foot, measured perpendicular to the topographic contour and described based on appropriately located subsurface explorations.
N.J. Admin. Code § 7:9A-10.7
See: 31 New Jersey Register 1416(a), 31 New Jersey Register 2741(a).
In (i)1, added a reference to dedicated seepage pits and dry wells.