Table 5:70-4.11(f)1 | ||||
CAPACITY PER UNIT EGRESS WIDTH | ||||
Without fire suppression system Number of occupants | With fire suppression system Number of occupants | |||
Use group | Stairways | Doors, Ramps and Corridors | Stairways | Doors, Ramps and Corridors |
A | 75 | 100 | 113 | 150 |
B | 60 | 100 | 90 | 150 |
E | 75 | 100 | 113 | 150 |
F | 60 | 100 | 90 | 150 |
H | -- | -- | 60 | 100 |
I-1 | 60 | 100 | 90 | 100 |
I-2 | 22 | 30 | 35 | 45 |
I-3 | 60 | 100 | 90 | 150 |
M | 60 | 100 | 90 | 150 |
R | 75 | 100 | 113 | 150 |
S | 60 | 100 | 90 | 150 |
Table 5:70-4.11(f)3 | |
Floor Area Per Occupant | |
Use | Occupant Load Factor in square |
feet per occupant | |
Assembly | |
Fixed seating | Note 1 |
Tables and chairs | 15 net |
Chairs only | 7 net |
Dance floors | 7 net |
Standing space | 5 net |
Waiting space (Note 2) | 3 net |
Bowling centers | |
Lanes | 5 persons |
Other areas | per assembly above |
Business | 100 gross |
Educational | |
Fixed seating | Note 1 |
Classrooms | 20 net |
Shops and vocational areas | 50 net |
Industrial | 100 gross |
Institutional | |
Inpatient treatment | 240 gross |
Outpatient | 100 gross |
Sleeping rooms | 120 gross |
Library | |
Reading room | 50 net |
Stack area | 100 gross |
Mercantile | |
Grade floor or basement | 30 gross |
All other floors | 60 gross |
Storage, stock, shipping | 300 gross |
Parking garages | 200 gross |
Residential | 200 gross |
Storage areas, mechanical equipment room | 300 gross |
Note 1. The occupant load for that portion of an assembly area having fixed seats shall be determined by the number of fixed seats installed. Capacity of seats without dividing arms is one person per 18 inches. For booths, one seat equals 24 inches. One person is allowed for each fixed seat with dividing arms or fixed stand alone stool.
Note 2. Waiting space means that space in an assembly occupancy where persons are admitted to the building at times when seats are not available to them and are allowed to wait in a lobby or similar space until seats are available. Such use of the lobby or similar space shall not encroach upon the required clear width of exits.
N.J. Admin. Code § 5:70-4.11