Total Occupancy 1,2, 3, 4 | Water Closets | Lavatories | Drinking Water Facilities | Service Sinks | |
1-15 | 1 Unisex | 1 | 1 | 1 | |
Employees | 16 and over | Fixtures to be provided as per Table 7.21.1 of the plumbing subcode. | |||
1-25 | 1 Unisex | 1 | 1 | 1 | |
Customers | 26 and over | Fixtures to be provided as per Table 7.21.1 of the plumbing subcode. |
Note 1. For purposes of determining the number of plumbing fixtures required, total occupancy shall be the anticipated occupancy of the building under normal use conditions. It is not necessarily the same as the total permitted occupant load based on egress capacity.
Note 2. Customer and employee facilities may be satisfied with a single unisex toilet facility where the number of employees does not exceed 15 and where the total occupancy does not exceed 25 or where the occupied floor area does not exceed 1,500 square feet.
Note 3. Requirements for employees and customers may be met with a single set of restrooms. The required number of fixtures shall be the greater of the required number for employees or customers.
Note 4. Regardless of total occupancy, exam rooms shall comply with Section 7.21.6e of the plumbing subcode.
N.J. Admin. Code § 5:23-6.17