N.J. Admin. Code § 19:6-2.36

Current through Register Vol. 56, No. 11, June 3, 2024
Section 19:6-2.36 - Minimum section

Except as provided in section 48 of this subchapter for timber piles, no tapered pile shall be less than six inches in diameter for any section, nor have less than an eight-inch diameter at cutoff. The taper of any tapered section may be uniform or may occur in steps. No pile of uniform section shall have a diameter of less than eight inches or, if not circular, a dimension of less than 7-1/2 inches. Tapered shoes or points of lesser dimensions may be attached to the tips of piles.

N.J. Admin. Code § 19:6-2.36