Current through Register Vol. 56, No. 21, November 4, 2024
Section 16:25-7A.4 - Design of facilities(a) Installations shall be of the underground type only and no above ground facilities of any kind will be permitted inside the limited access highway right-of-way.(b) Above or below ground regenerator or backup power manholes or enclosures shall not be permitted within limited access highway right-of-way.(c) Handholes for the purpose of cable splicing and/or installation shall be permitted and shall not extend above the surrounding ground.(d) Cable shall be placed in conduit.(e) Above ground warning signs bearing the public utility owner's name and contact number shall be mounted by the permittee upon adjacent control of access fencing at line-of-sight intervals or as specified in the agreement or permit.N.J. Admin. Code § 16:25-7A.4