N.J. Admin. Code § 13:39-11.8

Current through Register Vol. 56, No. 11, June 3, 2024
Section 13:39-11.8 - Use of compounding aseptic isolators and compounding aseptic containment isolators located outside of a cleanroom

A pharmacy may utilize compounding aseptic isolators and compounding aseptic containment isolators not located in a cleanroom to prepare compounded sterile preparations, provided the compounding aseptic isolators and compounding aseptic containment isolators can provide isolation from the room and maintain ISO class 5 air quality during dynamic operating conditions, including transferring ingredients, components, and devices into and out of the isolator and during preparation of compounded sterile preparations. Particle counts sampled approximately six to 12 inches upstream of the critical exposure site must maintain ISO class 5 air quality levels during compounding operations. Compounding personnel shall obtain documentation from the manufacturer that the compounding aseptic isolator or compounding aseptic containment isolator will meet this standard when located in worse than ISO class 7 environments. A compounding aseptic isolator and compounding aseptic containment isolator not located in a buffer area shall be located in an area that is maintained under sanitary conditions and such area shall only be traveled by persons engaging in the compounding of sterile preparations.

N.J. Admin. Code § 13:39-11.8

Amended by 49 N.J.R. 3761(a), effective 12/4/2017