Current through Register Vol. 57, No. 1, January 6, 2025
Section 12:190-10.2 - Smokeless powder(a) A cabinet for smokeless powder shall have walls at least one inch thick, with an interior of nonsparking material. Shelves shall not exceed a three foot separation. The cabinet shall have at least one lock and hinges and hasps that cannot be removed when the door is closed and locked.(b) Smokeless powder not exceeding 100 pounds intended for personal use may be stored in a residence. Smokeless powder not exceeding 36 pounds stored in residences shall be in approved USDOT shipping containers. Smokeless powder exceeding 36 pounds but not exceeding 100 pounds stored in a residence shall be in a cabinet, and not more than one cabinet shall be used.(c) Smokeless powder not exceeding 400 pounds intended for resale shall be stored in a warehouse or storage room which is not accessible to unauthorized personnel, or as provided in (d) below.(d) Smokeless powder not exceeding 400 pounds intended for resale shall be stored in non-portable storage cabinets as follows:1. Not more than two cabinets in a building and not more than 200 pounds of smokeless powder in a single cabinet.2. Cabinets located against walls of the warehouse or storage room with a minimum separation of 10 feet between cabinets.3. Cabinets separated from flammable liquids, flammable solids and oxidizing materials by a wall having a fire resistance rating of not less than one hour or by a distance of 25 feet.(e) Smokeless powder exceeding 400 pounds shall be stored in accordance with N.J.A.C. 12:190-5.N.J. Admin. Code § 12:190-10.2