N.H. Admin. Code § We 603.01

Current through Register No. 45, November 7, 2024
Section We 603.01 - Active Wells

Active wells shall be maintained as follows:

(a) A well casing shall not be terminated below ground surface, except as specified in We 602.35.
(b) A well with a casing inside diameter of 4 to 12 inches shall be equipped with a well cover with an o-ring, gasket or other seal to prevent the entrance of insects or other foreign matter into the well.
(c) A well with a casing inside diameter less than 4 inches shall be fitted with a secure cap or plug.
(d) A well constructed by excavation shall be equipped with a concrete cover or shall be enclosed in a locked structure specifically designed to house the well. Where a well house is provided, covers other than concrete shall be permitted.
(e) A monitoring well shall be fitted with a secured tamper proof well cover.

N.H. Admin. Code § We 603.01

#3046, eff 7-2-85; EXPIRED: 7-2-91

New. #6449, eff 1-29-97; ss by #7307, eff 6-13-00; ss by #9179, eff 6-13-08

Amended by Volume XXXVII Number 2, Filed January 12, 2017, Proposed by #12083, Effective 3/1/2017, Expires 3/1/2027.