N.H. Admin. Code § Saf-C 1635.01

Current through Register No. 36, September 5, 2024
Section Saf-C 1635.01 - Location of Buildings
(a) Buildings or other facilities used for mixing water gels shall be located with respect to inhabited buildings, passenger railroads and public highways, in accordance with the table of distance cited in Saf-C 1640.1.
(b) In determining the distances separating highways, railroads, and inhabited buildings from potential explosions, as prescribed in the table of distances, the sum of all masses that might propagate from either individual or combined donor masses shall be included. However, when ammonium nitrate must be included, only one-half of its weight shall be calculated because of its reduced blast effects.

N.H. Admin. Code § Saf-C 1635.01

#2220, eff 12-31-82; ss by #2837, eff 8-27-84; ss by #4584, eff 3-3-89; ss by #5996, INTERIM, eff 3-3-95, EXPIRES, 7-1-95; ss by #6054, eff 7-1-95, EXPIRED: 7-1-03

New. #8116, INTERIM, eff 7-14-04, EXPIRES: 1-10-05; ss by #8231, eff 12-20-04

Amended by Volume XXXIII Number 37, Filed September 12, 2013, Proposed by #10396, Effective 8/15/2013, Expires 8/15/2023.