All electrical switches, controls, motors, and lights located in mixing rooms shall conform to the requirements in the National Electrical Code, NFPA 70, 2002 edition, available as noted in Appendix I, for Class II, Division 2 locations, otherwise they shall be located outside the mixing room. The frame of the mixer and all other equipment that may be used shall be electrically bonded and be provided with a continuous path to the ground.
N.H. Admin. Code § Saf-C 1629.08
#2220, eff 12-31-82; ss by #2837, eff 8-27-84; ss by #4584, eff 3-3-89; ss by #5996, INTERIM, eff 3-3-95, EXPIRES, 7-1-95; ss by #6054, eff 7-1-95, EXPIRED: 7-1-03
New. #8116, INTERIM, eff 7-14-04, EXPIRES: 1-10-05; ss by #8231, eff 12-20-04